BACKGROUND During coronary stenosis, flow reserve in the adjacent nonstenotic bed decreases, but the microvascular mechanisms are unknown. Because myocardial contrast echocardiography (MCE) assesses microvascular physiology, we used it to relate flow reserve to intramyocardial blood volume in the adjacent bed. METHODS AND RESULTS A noncritical left anterior descending (LAD) stenosis was created in 10 dogs. MCE was performed and myocardial blood flow was measured with neutron-activated microspheres and flow probes. Data were collected at baseline, hyperemia, and hyperemia and stenosis. Hyperemia was induced with an A2A receptor agonist. MCE acoustic intensity in the LAD and left circumflex (LCx) regions were fit to the following: y=A(1-e(-beta t)), where A, beta, and A x beta reflect intramyocardial blood volume, red cell velocity, and flow, respectively. During hyperemia alone, LCx probe and microsphere flows and MCE-derived red cell velocity increased from baseline (30+/-14 versus 125+/-62 mL/min, P<0.0005; 1.5+/-0.5 versus 6.6+/-2.0 mL x min(-1) x g(-1), P<0.0005; and 0.53+/-0.14 versus 0.96+/-0.45 second(-1), P=0.030, respectively); intramyocardial blood volume was unchanged. LAD stenosis during hyperemia decreased LCx probe flow (125+/-62 versus 110+/-57 mL/min; P<0.05), microsphere flow (6.6+/-2.0 versus 4.2+/-2.1 mL x min(-1) x g(-1); P<0.0005), and MCE-derived flow (0.57+/-0.29 versus 0.45+/-0.33 second(-1); P=0.032). LCx bed intramyocardial blood volume concurrently increased (0.61+/-0.14 versus 0.70+/-0.15; P<0.01). CONCLUSIONS Coronary stenosis impairs flow reserve in the adjacent nonstenotic bed, in which intramyocardial blood volume increases. MCE suggests compensatory recruitment of microvascular anastomotic collateral networks that augment stenotic bed flow reserve, but at the expense of the adjacent bed. Adjacent bed collateral microcirculation thus participates in the regulation of collateral flow and appears functionally significant during coronary stenosis.
منابع مشابه
Noninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography.
BACKGROUND We hypothesized that coronary blood flow (CBF) reserve could be quantified noninvasively in humans using myocardial contrast echocardiography (MCE). METHODS AND RESULTS Eleven patients with normal epicardial coronary arteries (group I) and 19 with single-vessel coronary stenosis (group II) underwent quantitative coronary angiography, MCE, and CBF velocity measurements at rest and d...
متن کاملComparison of Fractional Flow Reserve Assessment With Demand Stress Myocardial Contrast Echocardiography in Angiographically Intermediate Coronary Stenoses.
BACKGROUND Real-time myocardial contrast echocardiography (RTMCE) directly measures capillary flow (CBF), which in turn is a major regulator of coronary flow and resistance during demand or hyperemic stress. Although fractional flow reserve (FFR) was developed to assess the physiological relevance of an epicardial stenosis, it assumes maximal microvascular vasodilation and minimal resistance du...
متن کاملDetection of Autoregulatory Changes in Nonstenotic Coronary Arteries Induced by Collateral Flow to Adjacent Stenotic Arteries
Background Our study compares the effect of acute proximal stenosis of a coronary artery supplying a myocardial perfusion bed with that of stenosis of an adjacent artery resulting in collateral flow diversion supplied by the same perfusion bed. These alterations in coronary physiology were quantified by digital angiographic impulse response analysis of contrast material mean transit time for th...
متن کاملTransthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment
This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR) in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery). Post-sten...
متن کاملDigital angiographic impulse response analysis of regional myocardial perfusion. Detection of autoregulatory changes in nonstenotic coronary arteries induced by collateral flow to adjacent stenotic arteries.
BACKGROUND Our study compares the effect of acute proximal stenosis of a coronary artery supplying a myocardial perfusion bed with that of stenosis of an adjacent artery resulting in collateral flow diversion supplied by the same perfusion bed. These alterations in coronary physiology were quantified by digital angiographic impulse response analysis of contrast material mean transit time for th...