Use of a bonding agent to reduce sealant sensitivity to moisture contamination: an in vitro study.

نویسندگان

  • J C Hitt
  • R J Feigal
چکیده

Moisture contamination of etched enamel during application of sealant is the most frequently cited reason for sealant failure. In preliminary studies, a dentin bonding agent (Scotchbond Dual Cure, 3M, St. Paul, MN) has been shown to bond adequately to etched enamel after salivary contamination. This study investigated bond strength in vitro, when a bonding agent was used beneath sealants under varied conditions of contamination. Five hundred bovine incisor crowns were separated randomly into eight groups. The enamel samples, etched for 60 sec with a 37% phosphoric acid gel, were contaminated with: 1) fresh whole saliva, air dried, 2) fresh whole saliva, left wet, or 3) moisture from a humidity chamber. All contamination conditions were tested for sealant bond strength with and without the bonding agent as an intermediate layer under the sealant. As controls, both sealant and bonding agent under sealant also were applied to clean etched enamel. Bond strength was measured using a universal testing machine. Data were analyzed using a two-way ANOVA. Under conditions of humidity or intact saliva, sealant alone showed significant reduction in bond strength (P less than 0.001). Bonding agent under sealant on wet contamination yielded bond strengths equivalent to the bond strength obtained when sealant was bonded directly to clean, etched enamel. Bonding agent used without contamination yielded bond strengths significantly greater than the bond strength obtained when using sealant alone without contamination (P less than 0.001). When the saliva was air dried onto the surface, there was no significant difference in bond strengths whether or not a bonding agent was used under the sealant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in vitro study of wet-bonding fissure sealant micro-leakage (Embrace)

An in vitro study of wet-bonding fissure sealant micro-leakage (Embrace) Dr. T. Masoum *- Dr. SH. Kasraie ** - Dr. M. Nafarie *** *Assistant Professor of Pedodontics Dept., Faculty of Dentistry, Hamedan University of Medical Sciences. **Assistant Professor of Operative Dentistry Dept., Faculty of Dentistry, Hamedan University of Medical Sciences. *** Dentist. Abstract Background and Aim: It has...

متن کامل

بررسی اثر آلودگی با بزاق بر روی ریزنشت یک نوع فیشور سیلنت با و بدون استفاده از باندینگ

Introduction: Contamination of etched enamel to saliva before placement of sealant prevents the appropriate bonding and results in microleakage. Using bondings is effective for decreasing the microleakage. This experimental study aimed to evaluate the effect of bonding agent on microleakage of a fissure sealant before or after contamination to saliva. Methods: In this experimental study 40 sou...

متن کامل

مقایسه کلینیکی تأثیر دو نوع باندینگ هیدروفیل و هیدروفوب در دوام و گیر فیشور سیلنت

Background and Aims: As in fissure sealant therapy the tooth surface is mostly enamel, the use of an enamel bonding agent (hydrophobic bonding agent) may be more cost effective than that of newer generations of bonding (hydrophilic bonding agents). The aim of this study was to compare the retention and durability of fissure sealant therapy when applying an enamel bonding agent, a dentin bondi...

متن کامل

Evaluation of Microleakage in Fissure Sealants following Contamination with Artificial Saliva at Different Curing Times with or without using bonding agent

Background and Aim: One of the important factors in microleakage of fissure sealants is saliva contamination. Researchers believe that applying bonding agents can reduce the microleakage. The present study compared the microleakage of a fissure sealant contaminated with artificial saliva at different curing times with or without using a bonding agent. Materials and Methods: In this in-vitro ...

متن کامل

بررسی میکروسکوپ الکترونی اثر پرایمر بر نفوذ سیلنت در مینای آلوده به بزاق

Background and Aims: Moisture contamination of etched enamel during application of sealant is the most frequently cited reason for sealant failure. In previous studies, some hydrophilic bonding agents have been shown to bond to etched enamel after salivary contamination. The purpose of this study was to evaluate the enamelsealant interface following the use of primer on the saliva contaminated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatric dentistry

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 1992