Acute improvement in global and regional left ventricular systolic function after percutaneous heart valve implantation in patients with symptomatic aortic stenosis.

نویسندگان

  • Fabrice Bauer
  • Hélène Eltchaninoff
  • Christophe Tron
  • Pierre-François Lesault
  • Carla Agatiello
  • Deborah Nercolini
  • Geneviève Derumeaux
  • Alain Cribier
چکیده

BACKGROUND The newly developed percutaneous heart valve (PHV) implantation technique decreases transaortic pressure gradient in patients with aortic stenosis. PHV replacement effects on left ventricular (LV) global and regional systolic function are currently unknown. METHODS AND RESULTS Eight patients with severe aortic stenosis had 2D echocardiography at baseline and 24 hours after PHV implantation to evaluate changes in LV volume and LV ejection fraction. Regional function, ie, both peak systolic anterior and posterior wall tissue velocity, as well as strain and strain rate imaging, were measured by tissue Doppler imaging from a short-axis view. At 24 hours, a significant reduction in transaortic mean pressure gradient (from 46+/-15 to 8+/-3 mm Hg; P<0.0001) was accompanied by an increase in aortic valve area (from 0.59+/-0.11 to 1.69+/-0.11 cm2; P<0.0001). LV end-diastolic volume remained unchanged (102+/-36 to 101+/-12 mL; P=NS), whereas LV ejection fraction increased (48+/-18% to 57+/-12%; P<0.01). Improvement in posterior wall displacement (posterior wall tissue velocity increased from 2.2+/-0.5 to 4.4+/-1.0 cm/s(-1); P=0.0003) and deformation (strain rate imaging increased from 1.0+/-0.3 to 1.9+/-0.7 s(-1), P=0.009, and strain increased from 11+/-5% to 17+/-9%; P=0.02) were observed. CONCLUSIONS Immediately after PHV replacement, improvement of LV global and regional systolic function was evidenced by tissue Doppler imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute regional improvement of myocardial function after interventional transfemoral aortic valve replacement in aortic stenosis: A speckle tracking echocardiography study

BACKGROUND Transcatheter aortic valve implantation (TAVI) is a promising therapy for patients with severe aortic stenosis (AS) and high perioperative risk. New echocardiographic methods, including 2D Strain analysis, allow the more accurate measurement of left ventricular (LV) systolic function. The goal of this study was to describe the course of LV reverse remodelling immediately after TAVI i...

متن کامل

[Severe aortic stenosis and cardiogenic shock: a therapeutic challenge].

Acute heart failure in patients with severe aortic stenosis and left ventricular systolic dysfunction is well known for its dire prognosis and limited therapeutic options. The authors describe the case of a man admitted for non-ST-elevation myocardial infarction. Diagnostic exams revealed severe aortic stenosis, with good left ventricular systolic function, and two-vessel coronary artery diseas...

متن کامل

Similar Morphology, but Different Function: Acute Improvement of Myocardial Longitudinal Strain after Percutaneous Transcatheter Aortic Valve Implantation Therapy in a Severe Aortic Stenosis Patient

Left ventricular systolic function can be worsened as a result of long standing pressure overload in patients with aortic stenosis (AS). Two-dimensional speckle tracking echocardiography can detect decreased global longitudinal strain (GLS) even in patients with preserved left ventricular ejection fraction. Transcatheter aortic valve implantation (TAVI) is a newly introduced therapy for elderly...

متن کامل

Acute left ventricle diastolic function improvement after transcatheter aortic valve implantation.

AIMS Data regarding the effects of TAVI on LV after are scarce and conflicting results have been reported immediately after aortic valvuloplasty. This study aimed to determine the acute haemodynamic effects of transcatheter aortic valve implantation (TAVI) in left ventricle (LV) diastolic performance, immediately after aortic valvuloplasty and prosthesis deployment. METHODS AND RESULTS Sixty-...

متن کامل

Effects of transcatheter aortic valve implantation on left ventricular mass and global longitudinal strain: tissue Doppler and strain evaluation

INTRODUCTION Transcatheter aortic valve implantation is the option of choice for high surgical risk patients suffering from symptomatic aortic stenosis. We aimed to evaluate the influence of baseline global longitudinal strain on left ventricular mass regression after the procedure. METHODS We enrolled 23 patients with pure symptomatic severe aortic stenosis who underwent CoreValve prosthesis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 110 11  شماره 

صفحات  -

تاریخ انتشار 2004