Use of a noninvasive pulse CO-oximeter to measure blood carboxyhemoglobin levels in bingo players.

نویسندگان

  • Neil B Hampson
  • Karen L Scott
چکیده

BACKGROUND Though smokers are known to have elevated blood carboxyhemoglobin (COHb), due to inhalation of carbon monoxide (CO) in cigarette smoke, limited data exist regarding COHb levels in nonsmokers exposed to secondhand smoke. METHODS COHb was measured using a new noninvasive pulse CO-oximeter (Rad-57, Masimo, Irvine, California) in 38 subjects entering a bingo hall where smoking was allowed, then again as they exited 3 hours later. RESULTS The mean +/- SD baseline COHb for the entire group was 3.3 +/- 1.8%, for the 23 nonsmokers it was 2.2 +/- 0.7%, and for the 15 smokers it was 4.9 +/- 1.9%. The nonsmokers' mean COHb was unchanged, at 2.2 +/- 0.8%, whereas the smokers' mean COHb fell to 3.2 +/- 1.9%. CONCLUSIONS The nonsmokers were not significantly exposed to CO from secondhand smoke in the setting we tested. The smokers probably consumed fewer cigarettes while playing bingo than they did prior to arrival. The Rad-57 pulse CO-oximeter is easy to use in the ambulatory setting.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.

BACKGROUND A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. METHODS Ten volunteers breathed 50...

متن کامل

Reliability of new pulse CO-oximeter in victims of carbon monoxide poisoning.

STUDY OBJECTIVE The purpose of this study was to evaluate the reliability of noninvasive real-time measurement of carboxyhemoglobin (COHb) using a pulse CO-oximeter in victims of carbon monoxide poisoning (COP). METHODS During the 7-month study period, pulse CO-oximetry was measured on patients admitted to the emergency department (ED) for suspected COP. Each patient included in the study und...

متن کامل

Pulse carboxyhemoglobin-oximetry and cigarette smoking.

PURPOSE We used a pulse carbon monoxide (CO)-oximeter to measure the levels of carboxyhemoglobin (COHb) in smokers and non-smokers. Our goal was to determine if this device could not only define smoking status, but also to increase accuracy of self-reported data at various surveys on smoking. METHODS Thirty-four healthy volunteers participated in this study. Twenty-two of them were current da...

متن کامل

The current status of continuous noninvasive measurement of total, carboxy, and methemoglobin concentration.

Intraoperative early detection of anemia, identifying toxic levels of carboxyhemoglobin after carbon monoxide exposure and titrating drug dosage to prevent toxic levels of methemoglobin are important goals. The pulse oximeter works by illuminating light into the tissue and sensing the amount of light absorbed. The same methodology is used by laboratory hemoglobinometers to measure hemoglobin co...

متن کامل

A Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination

Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 51 7  شماره 

صفحات  -

تاریخ انتشار 2006