Measurements of Cherenkov Photons with Silicon Photomultipliers

نویسنده

  • S. Korpar
چکیده

A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research facility. This type of RICH detector is a candidate for the particle identification detector upgrade of the BELLE detector at the KEK B-factory, for which the use of SiPMs, microchannel plate photomultiplier tubes or hybrid avalanche photodetectors, rather than traditional Photomultiplier Tubes (PMTs), is essential due to the presence of high magnetic fields. In both experiments, SiPMs are found to compare favourably with PMTs, with higher photon detection rates per unit area. Through the use of hemispherical and truncated pyramid light guides to concentrate photons onto the active surface area, the light yield increases significantly. An estimate of the contribution to dark noise from false coincidences between SiPMs in an array is also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cherenkov luminescence measurements with digital silicon photomultipliers: a feasibility study

BACKGROUND A feasibility study was done to assess the capability of digital silicon photomultipliers to measure the Cherenkov luminescence emitted by a β source. Cherenkov luminescence imaging (CLI) is possible with a charge coupled device (CCD) based technology, but a stand-alone technique for quantitative activity measurements based on Cherenkov luminescence has not yet been developed. Silico...

متن کامل

Multianode photomultipliers as position-sensitive detectors of single photons

Tests of 2300 Hamamatsu multianode photomultipliers (1543 pieces of R5900-M16 and 762 pieces of R5900-M4) have been tested on the bench in order to evaluate their performance for use as position-sensitive photon detectors in the ring imaging Cherenkov counter of the HERA-B experiment.1 A weak and stable source of photons has been obtained by Cherenkov radiation of electrons from a 90Sr source i...

متن کامل

BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET.

Due to detector developments in the last decade, the time-of-flight (TOF) method is now commonly used to improve the quality of positron emission tomography (PET) images. Clinical TOF-PET systems based on L(Y)SO:Ce crystals and silicon photomultipliers (SiPMs) with coincidence resolving times (CRT) between 325 ps and 400 ps FWHM have recently been developed. Before the introduction of L(Y)SO:Ce...

متن کامل

Performance of Silicon Photomultipliers in photon number and time resolution

Silicon Photomultipliers (SiPMs) are a novel generation of photon detectors designed as an array of independently operated Geiger-mode APDs (pixels) with common output. SiPM provides proportional detection of low-level light pulses starting from single photons with remarkable photon number and time resolution at room temperature. Now they are worldwide recognized to be competitive with vacuum p...

متن کامل

A Method of Coating Photomultipliers with Wavelength Shifters

A simple procedure to coat photomultipliers with PTP wavelength shifter is described and results of some measurements are discussed. 1. Introduction The spectral sensitivity in the UV region of modem photomultipliers is normally limited by the transmission properties of the window material. The glass windows commonly used typically absorb light below a 300 nm wavelength. In many applications , ...