Numerical investigations of pulsatile flow in stenosed artery.

نویسندگان

  • Arindam Bit
  • Himadri Chattopadhyay
چکیده

PURPOSE Abnormalities in blood vessels by virtue of complex blood flow dynamics is being supported by non-Newtonian behavior of blood. Thus it becomes a focus of research to most of the researchers. Additionally, consideration of real life patient specific model of vessel as well as patient specific inlet flow boundary condition implementation was limited in literature. Thus a thorough implementation of these considerations was done here. METHOD In this work, a numerical investigation of hemodynamic flow in stenosed artery has been carried out with realistic pulsating profile at the inlet. Flow has been considered to be laminar due to arresting condition of cardiovascular state of the subject. Two non- Newtonian rheological models namely, Power Law viscosity model and Quemada viscosity model have been used. Two different patient- specific pulsatile profiles are considered at the inlet of a long stenosed artery with varying degree of stenoses from 25% to 80%. RESULTS Transient form of Navier-Stokes equation is solved in an axi-symmetric domain to calculate the detailed flow structure of the flow field. From the simulation data, temporal and time averaged wall shear stress, oscillatory shear index and pressure drop are calculated. CONCLUSIONS The results demonstrate that oscillatory shear index and wall shear stresses are extensively governed by the degree of stenoses. The position and movement of recirculation bubbles are found to vary with flow Reynolds number.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery

A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...

متن کامل

Numerical Investigation of Angulation Effects in Stenosed Renal Arteries

Background: Numerical study of angulation effects of renal arteries on blood flow has been of great interest for many researchers.Objective: This paper aims at numerically determining the angulation effects of stenosed renal arteries on blood flow velocity and renal mass flow.Method: An anatomically realistic model of abdominal aorta and renal arteries is reconstructed from CT-scan images and u...

متن کامل

An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery

With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...

متن کامل

Numerical Modeling of Two-Layered Micropolar Fluid Through an Normal and Stenosed Artery

In the present work a two fluid model for blood flow through abnormally constrictedhuman artery (stenosed artery) has been developed. The model consists of a core region of suspensionof all erythrocytes assumed to be micro-polar fluid so as to include the micro-structural effects inaddition to the peripheral-layer viscosity effects, and a peripheral plasma layer free from cells of anykind of Ne...

متن کامل

Mathematical modeling of blood flow in a stenosed artery under MHD effect through porous medium

In this investigation, a mathematical model for studying oscillatory flow of blood in a stenosed artery under the influence of transverse magnetic field through porous medium has been developed. The equations of motion of blood flow are solved analytically. The analytical expressions for axial velocity, volumetric flow rate, pressure gradient, resistance to blood flow and shear stress have been...

متن کامل

Oscillatory MHD Flow of Blood through an Artery with Mild Stenosis (RESEARCH NOTE)

The purpose of this work is to study the effect of oscillatory MHD blood flow in stenosed artery. The analytical and numerical results are obtained for oscillatory MHD blood flow, which is assumed to be a Newtonian fluid. It was also assumed that the surface roughness is of cosine shaped and the maximum height of roughness is negligible, compared with the radius of un-constricted tube. The flui...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta of bioengineering and biomechanics

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2014