The CUSUM chart method as a tool for continuous monitoring of clinical outcomes using routinely collected data

نویسندگان

  • Thabani Sibanda
  • Nokuthaba Sibanda
چکیده

BACKGROUND The lack of robust systems for monitoring quality in healthcare has been highlighted. Statistical process control (SPC) methods, utilizing the increasingly available routinely collected electronic patient records, could be used in creating surveillance systems that could lead to rapid detection of periods of deteriorating standards. We aimed to develop and test a CUmulative SUM (CUSUM) based surveillance system that could be used in continuous monitoring of clinical outcomes, using routinely collected data. The low Apgar score (5 minute Apgar score < 7) was used as an example outcome. METHOD A surveillance system based on the Observed minus Expected (O-E) as well as the 2-sided Log-Likelihood CUSUM charts was developed. The Log-Likelihood chart was designed to detect a 50% rise (deterioration) and halving (improvement) in the odds of low Apgar scores. Baseline rates were calculated from data for 2001 to 2004, and were used to monitor deliveries for 2005. Deliveries for nulliparous and multiparous women were monitored separately. All analyses were retrospective. RESULTS The CUSUM system detected periods of increased rates of low Apgar scores for each of the nulliparous and multiparous cohorts. The overall rate for 2005 was eventually found to be 0.67%, which was higher than the baseline reference rate of 0.44% from 2001 to 2004. CONCLUSION CUSUM methods can be used in continuous monitoring of clinical outcomes using routinely collected data. Used prospectively, they could lead to the prompt detection of periods of suboptimal standards.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A two-sided Bernoulli-based CUSUM control chart with autocorrelated observations

Usually, in monitoring a proportion p < /em>, the binary observations are considered independent; however, in many real cases, there is a continuous stream of autocorrelated binary observations in which a two-state Markov chain model is applied with first-order dependence. On the other hand, the Bernoulli CUSUM control chart which is not robust to autocorrelation can be applied two-sided co...

متن کامل

A risk adjusted self-starting Bernoulli CUSUM control chart with dynamic probability control limits

Usually, in monitoring schemes the nominal value of the process parameter is assumed known. However, this assumption is violated owing to costly sampling and lack of data particularly in healthcare systems. On the other hand, applying a fixed control limit for the risk-adjusted Bernoulli chart causes to a variable in-control average run length performance for patient populations with dissimilar...

متن کامل

Monitoring Lognormal Reliability Data in a Two-Stage Process Using Accelerated Failure Time Model

The reliability data is getting used to monitor and improve the quality of products or services. Nowadays, most of products or services are the results of processes with dependent stages referred to as multi-stage process. In these processes, the quality characteristics are affected by the quality characteristics in the previous stages, called as cascade property. In some cases, it is not possi...

متن کامل

A Self-starting Control Chart for Simultaneous Monitoring of Mean and Variance of Simple Linear Profiles

In many processes in real practice at the start-up stages the process parameters are not known a priori and there are no initial samples or data for executing Phase I monitoring and estimating the process parameters. In addition, the practitioners are interested in using one control chart instead of two or more for monitoring location and variability of processes. In this paper, we consider a s...

متن کامل

A new chart-independent method for fast identification of control level of industrial processes using continuous data

A new method is developed for a fast identification of the stability situation of industrial processes. The proposed method includes two factor ratios of the control constants for the upper and lower control limits to process these constants. An indication ratio is then defined as the ratio of the maximum data range value to the difference between the maximum and average values for individual d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BMC Medical Research Methodology

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2007