[Quantitative evaluation of X-ray opacity of the maxillary sinus using a digital disposition system].

نویسندگان

  • T Saiki
  • E Yumoto
  • H Okamura
چکیده

The authors attempted to obtain a quantitative index of X-ray opacity of the maxillary sinus using a digital disposition system. X-ray films of the Waters' view were used for analysis. A cooper wedge was placed on the left side of the subject's face and was simultaneously filmed. The wedge was made of copper plates increased in thickness from 0.2 to 4.0 mm in 20 steps and serving as a calibration standard. The subject-to-film distance was kept constant at one meter. The voltage and current of the X-ray tube were 85 kV and 200 mA, respectively. The X-ray films were digitized with a film-digitizer (Toshiba, TDF-500B). The X-ray opacity from 0.0 to 4.0 was transformed to 1024 steps and the whole X-ray film was divided into 512 x 512 pixels. Then, the X-ray density of each pixel was converted to an absolute value of wedge thickness with a medical image processor (Toshiba, GMS-500U). The mean pixel values in the region of interest (ROI) of the maxillary sinus and that of the whole maxillary sinus were named MR and MW, respectively. The mean pixel value in the ROI of the ipsilateral orbita was called O. We used MR, MW, MR -O and MW -O as indices. The results were as follows: 1. MR, MW, MR -O and MW -O were useful in quantitative evaluation of the X-ray opacity of the maxillary sinus in a subject. 2. MR -O and MW -O were also good references for comparing the X-ray opacity of the maxillary sinus among different subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Unbelievable Foreign Body in a Maxillary Sinus

Introduction: Misdiagnosis and the resulting mismanagement are challenging issues in complicated cases which present with obscure complaints. Interpreting radiologic studies, especially conventional plain radiologic images, remains the most frequently prescribed and useful modality for the first step of assessment. Case Presentation: In this report, we present...

متن کامل

Ectopic Molar with Maxillary Sinus Drainage Obstruction and Oroantral Fistula

Introduction: Ectopic tooth eruption may result owing to one of 3 processes: developmentalDisturbance, iatrogenic activity, or pathologic process, such as a tumor or a cyst. In rare cases, occlusion of the sinus ostia may predispose a patient to develop a maxillary sinus mucocele. When the maxillary sinus is invaded, symptoms usually occur late in the process.   Case report: A 17 years old boy...

متن کامل

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

متن کامل

Comparison of the Distances between the Maxillary Sinus Floor and Root-Tips of the First and Second Maxillary Molar Teeth Using Panoramic Radiography among Dolichocephalic and Brachycephalic and Mesocephalic Individuals

Introduction: Comparison of the relationships and distance between maxillary root tips and   the maxillary sinus floor using oral panoramic in the dolichocephalic and brachycephalic compared to mesocephalic individuals. Methods: Oral panoramic images from 300 individuals were analyzed and the relationships and distance between the maxillary root tips and the sinus floor was assessed by qualitat...

متن کامل

Radiographic assessment of findings in the maxillary sinus using cone-beam computed tomography.

OBJECTIVES. To assess the presence of anatomic variations and pathology of the maxillary sinus using cone beam computed tomography (CBCT) of the maxilla where pre- implant surgery is planned. MATERIAL AND METHODS. This retrospective study evaluates a sample CBCT scans of 34 dental patients (68 sinuses). CBCT is used to assess maxillary sinus mucosa and outflow and prevalence of septa. The mucos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Jibiinkoka Gakkai kaiho

دوره 96 11  شماره 

صفحات  -

تاریخ انتشار 1993