Quantification of liver fat in mice: comparing dual-echo Dixon imaging, chemical shift imaging, and 1H-MR spectroscopy.

نویسندگان

  • Xin-Gui Peng
  • Shenghong Ju
  • Yujiao Qin
  • Fang Fang
  • Xin Cui
  • George Liu
  • Yicheng Ni
  • Gao-Jun Teng
چکیده

We evaluated dual-echo Dixon in-phase and out-of-phase (IP-OP), chemical shift imaging (CSI), and (1)H MRS (hydrogen MR spectroscopy) in estimating fat content (FC) in phantoms and in livers of mice. Phantoms were made according to the volume percentage of fat ranging from 0% to 100%. The three MR methods were performed to measure FC in phantoms and in livers of obese leptin-deficient (ob/ob), human BSCL2/seipin gene knockout (SKO), and wild-type (WT) mice. The results were compared with known FC in phantoms and to a reference standard from mice by histological semiautomatic vacuole segmentation (HIS-S) procedure and liver lipid (LL) chemical analysis. In phantoms, CSI underestimated FC from 50% to 100%, to a lesser extent than IP-OP. In vivo, liver FC in ob/ob and SKO mice measured by the three MR methods were all significantly higher than that in WT mice. Liver FC measured by IP-OP were significantly lower than that measured by CSI and MRS, with no significant difference between CSI and MRS. CSI and MRS showed a linear correlation with LL analysis and with each other. IP-OP underestimated FC, whereas CSI and MRS were more accurate for quantifying FC in both phantoms and liver. CSI and MRS have the potential to replace HIS-S and LL analysis in longitudinal studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of hepatic steatosis using dual-energy CT with MR comparison.

In this study, we aimed to explore the potential of dual-energy computed tomography (DECT) in evaluating liver fat; we also compared the diagnostic performance of DECT, T1-weighted dual-echo magnetic resonance (MR) imaging, and 1H-MR spectroscopy (1H-MRS) in assessing hepatic steatosis in a fatty liver rat model. Fat (water) concentration measurements by DECT spectral imaging, MR findings, and ...

متن کامل

Fat content quantification errors using multiple gradient echo imaging: A phantom and simulation study

Introduction In the past decade, the incidence increase of obesity, diabetes and lipid metabolism disorders involved an epidemic increase of Non-Alcoholic Fatty Liver Diseases (NAFLD) which may affect from 10 to 30% of adults and 13% of children in the occidental population. NAFLD can evolve to Non-Alcoholic Steato-Hepatitis (NASH) and may lead to liver fibrosis up to cirrhosis from which compl...

متن کامل

Comparison of Multi-Echo Dixon Methods with Volume Interpolated Breath-Hold Gradient Echo Magnetic Resonance Imaging in Fat-Signal Fraction Quantification of Paravertebral Muscle

OBJECTIVE To assess whether multi-echo Dixon magnetic resonance (MR) imaging with simultaneous T2* estimation and correction yields more accurate fat-signal fraction (FF) measurement of the lumbar paravertebral muscles, in comparison with non-T2*-corrected two-echo Dixon or T2*-corrected three-echo Dixon, using the FF measurements from single-voxel MR spectroscopy as the reference standard. M...

متن کامل

Background Gradient Correction for Water and Fat Quantification in 2D Liver Imaging

Introduction Fatty infiltration of the liver is one of the primary features of nonalcoholic fatty liver disease. Therefore, accurate quantification of the liver fat content is an important factor in detecting hepatic diseases. MRI is an efficient noninvasive tool for assessing liver fat content. A commonly used liver fat quantification technique with MRI is a dual echo imaging (two gradient seq...

متن کامل

Is MR Spectroscopy Really the Best MR-Based Method for the Evaluation of Fatty Liver in Diabetic Patients in Clinical Practice?

OBJECTIVE To investigate if magnetic resonance spectroscopy (MRS) is the best Magnetic Resonance (MR)-based method when compared to gradient-echo magnetic resonance imaging (MRI) for the detection and quantification of liver steatosis in diabetic patients in the clinical practice using liver biopsy as the reference standard, and to assess the influence of steatohepatitis and fibrosis on liver f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of lipid research

دوره 52 10  شماره 

صفحات  -

تاریخ انتشار 2011