Accuracy of Needle Placement in Cadavers: Non-Guided Versus Ultrasound-Guided
نویسندگان
چکیده
OBJECTIVE To compare the accuracy rates of non-guided vs. ultrasound-guided needle placement in four lower limb muscles (tibialis posterior, peroneus longus, and short and long heads of the biceps femoris). METHODS Two electromyographers examined the four muscles in each of eight lower limbs from four fresh frozen cadavers. Each electromyographer injected an assigned dye into each targeted muscle in a lower limb twice (once without guidance, another under ultrasound guidance). Therefore, four injections were done in each muscle of one lower limb. All injections were performed by two electromyographers using 18 gauge 1.5 inch or 24 gauge 2.4 inch needles to place 0.5 mL of colored acryl solution into the target muscles. The third person was blinded to the injection technique and dissected the lower limbs and determined injection accuracy. RESULTS A 71.9% accuracy rate was achieved by blind needle placement vs. 96.9% accuracy with ultrasound-guided needle placement (p=0.001). Blind needle placement accuracy ranged from 50% to 93.8%. CONCLUSION Ultrasound guidance produced superior accuracy compared with that of blind needle placement in most muscles. Clinicians should consider ultrasound guidance to optimize needle placement in these muscles, particularly the tibialis posterior.
منابع مشابه
Ultrasound-guided percutaneous tracheal puncture: a computer-tomographic controlled study in cadavers.
BACKGROUND Ultrasound-guided techniques are increasingly used in anaesthetic practice to identify tissues beneath the skin and to increase the accuracy of placement of needles close to targeted structures. To examine ultrasound's usefulness for dilatational tracheostomy, we performed ultrasound-guided tracheal punctures in human cadavers followed by computer-tomographic (CT) control. METHODS ...
متن کاملThe Effects of Ultrasound-Guided Dry Needling on Patients With Myofascial Pain Syndrome: A Review Study
Objectives: Dry Needling (DN) is a novel and effective intervention for patients with Myofascial Pain Syndrome (MPS). Some characteristics, such as needle penetration depth, needle insertion into the target muscle, and trigger points must be identified in this intervention. The Ultrasound (US)-guided DN is a technique that involves needle insertion at the site of injury and the simulation of ti...
متن کاملUltrasound-Guided Superior Hypogastric Plexus Block: A Cadaveric Feasibility Study with Fluoroscopic Confirmation.
Plancarte first described a fluoroscopy-guided superior hypogastric plexus block to manage pelvic pain in 1990. Modifications have since been described using different imaging modalities. Ultrasound-guided approach has been described in a clinical outcome study. However, the accuracy of an ultrasound-guided method has never been validated by alternative imaging. We conducted an experiment aimin...
متن کاملClinical utility of ultrasound guidance for intra-articular knee injections: a review
Intra-articular corticosteroid and hyaluronic acid injections provide short-term symptom amelioration for arthritic conditions involving structural damage or degenerative changes in the knee. Conventional palpation-guided anatomical injections frequently result in inaccurate needle placement into extra-articular tissue and adjacent structures. The purpose of this review was to determine the eff...
متن کاملLung Lesions Biopsy in Children by Computed Tomography (CT) Fluoroscopy Guided Versus Conventional CT Scan Guided
Abstract Background Computed tomography (CT)-guided biopsy of the lung is a well-established method of diagnosis. The aim of this study was to determine the success rate of fluoroscopic CT (FCT) and conventional CT (CCT) in needle navigation biopsies from the lung lesions. Materials and Methods A total of 78 patients were prospectively enrolled to receive CT-guided biopsy with (group I, n=2...
متن کامل