Is there sufficient evidence for tuning fork tests in diagnosing fractures? A systematic review
نویسندگان
چکیده
OBJECTIVE To determine the diagnostic accuracy of tuning fork tests for detecting fractures. DESIGN Systematic review of primary studies evaluating the diagnostic accuracy of tuning fork tests for the presence of fracture. DATA SOURCE We searched MEDLINE, CINAHL, AMED, EMBASE, Sports Discus, CAB Abstracts and Web of Science from commencement to November 2012. We manually searched the reference lists of any review papers and any identified relevant studies. STUDY SELECTION AND DATA EXTRACTION Two reviewers independently reviewed the list of potentially eligible studies and rated the studies for quality using the QUADAS-2 tool. Data were extracted to form 2×2 contingency tables. The primary outcome measure was the accuracy of the test as measured by its sensitivity and specificity with 95% CIs. DATA SYNTHESIS We included six studies (329 patients), with two types of tuning fork tests (pain induction and loss of sound transmission). The studies included patients with an age range 7-60 years. The prevalence of fracture ranged from 10% to 80%. The sensitivity of the tuning fork tests was high, ranging from 75% to 100%. The specificity of the tests was highly heterogeneous, ranging from 18% to 95%. CONCLUSIONS Based on the studies in this review, tuning fork tests have some value in ruling out fractures, but are not sufficiently reliable or accurate for widespread clinical use. The small sample size of the studies and the observed heterogeneity make generalisable conclusion difficult.
منابع مشابه
Validation of tuning fork test in stress fractures and its comparison with radionuclide bone scan.
BACKGROUND Stress fractures are quite common both in athletes and military recruits. The purpose of the study was to evaluate the efficacy of tuning fork in stress fractures by comparing it with three phase bone scan. METHODS The current study examined 55 subjects whose age ranged 18-28 years. X-rays of all the subjects were unremarkable. After history and clinical examination tuning fork tes...
متن کاملAcromial Stress Fractures: A Systematic Review
Background: Acromial stress fracture (ASF) is a unique complication of reverse shoulder arthroplasty (RSA) thatcan have substantial influence on clinical results. The purpose of this review is to describe demographics, functionaloutcomes, and union rates for cases of RSA complicated by ASF.Methods: A systematic review was conducted using Preferred Reporting Items for Systemati...
متن کاملTuning Fork Tests
This article reviews the history of tuning fork tests, its current status as a clinical examination tool. All the commonly performed tuning fork tests are discussed in detail. The three commonly performed tuning fork tests include: Rinne test, weber test and Absolute bone conduction test.
متن کاملReliability of Semmes-Weinstein Monofilaments and Tuning Fork on Pressure and Vibration Sensation Measurements in Diabetic Patients
Objectives: Sensory neuropathy is the major cause of ulceration in diabetic patients. Periodical sensory examination is an appropriate method to detect neuropathy and decrease the risk of diabetic foot ulcer. Semmes–Weinstein Monofilaments (SWM) and tuning fork on/off test are widely used to assess pressure and vibration sensitivity. The present study evaluated the inter- and intra-rater reliab...
متن کاملTitanium Elastic Nails Versus Spica Cast in Pediatric Femoral Shaft Fractures: A Systematic Review and Meta-analysis of 1012 Patients
Background: There is a general consensus on the management of femoral fractures in children younger than two years and adolescents older than sixteen years. The best treatment for patients younger than sixteen years of age is still debatable. Titanium Elastic Nails (TEN), is widely used with some evidence, nonetheless, we undertook a systematic meta-analysis to assess the efficacy of TEN comp...
متن کامل