Pathology of second-generation everolimus-eluting stents versus first-generation sirolimus- and paclitaxel-eluting stents in humans.

نویسندگان

  • Fumiyuki Otsuka
  • Marc Vorpahl
  • Masataka Nakano
  • Jason Foerst
  • John B Newell
  • Kenichi Sakakura
  • Robert Kutys
  • Elena Ladich
  • Aloke V Finn
  • Frank D Kolodgie
  • Renu Virmani
چکیده

BACKGROUND Clinical trials have demonstrated that the second-generation cobalt-chromium everolimus-eluting stent (CoCr-EES) is superior to the first-generation paclitaxel-eluting stent (PES) and is noninferior or superior to the sirolimus-eluting stent (SES) in terms of safety and efficacy. It remains unclear whether vascular responses to CoCr-EES are different from those to SES and PES because the pathology of CoCr-EES has not been described in humans. METHODS AND RESULTS A total of 204 lesions (SES=73; PES=85; CoCr-EES=46) from 149 autopsy cases with duration of implantation >30 days and ≤3 years were pathologically analyzed, and comparison of vascular responses was corrected for duration of implantation. The observed frequency of late and very late stent thrombosis was less in CoCr-EES (4%) versus SES (21%; P=0.029) and PES (26%; P=0.008). Neointimal thickness was comparable among the groups, whereas the percentage of uncovered struts was strikingly lower in CoCr-EES (median=2.6%) versus SES (18.0%; P<0.0005) and PES (18.7%; P<0.0005). CoCr-EES showed a lower inflammation score (with no hypersensitivity) and less fibrin deposition versus SES and PES. The observed frequency of neoatherosclerosis, however, did not differ significantly among the groups (CoCr-EES=29%; SES=35%; PES=19%). CoCr-EES had the least frequency of stent fracture (CoCr-EES=13%; SES=40%; PES=19%; P=0.007 for CoCr-EES versus SES), whereas fracture-related restenosis or thrombosis was comparable among the groups (CoCr-EES=6.5%; SES=5.5%; PES=1.2%). CONCLUSIONS CoCr-EES demonstrated greater strut coverage with less inflammation, less fibrin deposition, and less late and very late stent thrombosis compared with SES and PES in human autopsy analysis. Nevertheless, the observed frequencies of neoatherosclerosis and fracture-related adverse pathological events were comparable in these devices, indicating that careful long-term follow-up remains important even after CoCr-EES placement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Second- versus first-generation drug-eluting stents for diabetic patients: a meta-analysis

INTRODUCTION The issue of whether various drug-eluting stents (DES) provide similar benefit in diabetic patients with coronary artery disease remains unclear. The purpose of the study is to assess the clinical utility of the second-generation and first-generation DES in patients with diabetes mellitus by a meta-analysis. MATERIAL AND METHODS A systematic literature search of PubMed, EMBASE, a...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

متن کامل

Next-generation drug-eluting stents in coronary artery disease: focus on everolimus-eluting stent (Xience V®)

Percutaneous coronary revascularization has been a mainstay in the management of coronary artery disease since its introduction in the late 1970s. Bare-metal stents and, more recently, first-generation drug-eluting stents (DES), such as sirolimus-eluting (Cypher) and paclitaxel-eluting stents (Taxus), have further improved results of percutaneous coronary intervention (PCI) by improving early r...

متن کامل

Update on the everolimus-eluting coronary stent system: results and implications from the SPIRIT clinical trial program

Drug-eluting stents (DES) have had a major impact in interventional cardiology. Compared to bare metal stents, they significantly reduce restenosis and the need for target vessel revascularization. Four DES are available in the US, the first-generation sirolimus-eluting (Cypher((R))) and paclitaxel-eluting (Taxus((R))) stents and later approved second-generation everolimus-eluting (Xience V((R)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 129 2  شماره 

صفحات  -

تاریخ انتشار 2014