Major hemorrhagic and thromboembolic complications in patients with mechanical heart valves receiving oral anticoagulant therapy.

نویسندگان

  • Przemysław Trzeciak
  • Marian Zembala
  • Lech Poloński
چکیده

INTRODUCTION Patients with mechanical heart valve prostheses are obligated to receive lifelong oral anticoagulant therapy to prevent thromboembolic complications; however, this treatment is associated with an increased risk of bleeding. The aim of this study was to evaluate the frequency of major hemorrhagic and thromboembolic complications in patients with mechanical heart valves who received oral anticoagulant therapy. MATERIALS AND METHODS The analysis involved 225 patients who underwent successful surgery in 2000; the mean (+/-SD) follow-up period was 43.3 +/- 9.2 months. Aortic, mitral, and double valve replacement was performed in 128 (56.7%), 70 (31.1%), and 27 (12.1%) of the patients, respectively. There were 128 men (57.3%), and the mean patient age was 57.9 +/- 18.8 years. The following data were assessed: rate of major hemorrhagic and thromboembolic complications, frequency of international normalized ratio (INR) rate measurements, and percentage of results within the therapeutic range. RESULTS Major hemorrhagic and thromboembolic complications occurred in 25 patients (11.1%). Seventeen patients (7.5%) survived, and 8 (3.6%) died of the complications. Major hemorrhagic and thromboembolic complications occurred in 17 patients (7.6%) and 8 patients (3.6%), respectively. The mean time between sequential measurements was 4.3 +/- 3.0 weeks, and of all the INR values collected, 42.4% were within, 31.3% were below, and 26.3% were above the target ranges. CONCLUSIONS Patients with a mechanical heart valve prosthesis receiving acenocoumarol are susceptible to major hemorrhagic and thromboembolic complications, some of which lead to death. Despite the danger related to these complications, patients receiving anticoagulant therapy still have difficulty achieving INR values within the therapeutic range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the occurrence of thromboembolic and bleeding complications in patients with mechanical heart valve prosthesis with one and two leaflets in the mitral position

INTRODUCTION Patients with mechanical heart valve prostheses must continuously be treated with oral anticoagulants to prevent thromboembolic events related to prosthetesis. These patients should be continually evaluated for the control of oral anticoagulation. OBJECTIVE To compare the occurrence of thromboembolic and hemorragic complications in patients with mechanical heart valve prosthesis ...

متن کامل

The Effect of a Nurse-led Patient Education Program for Oral Anticoagulant Therapy on the Incidence of Thromboembolic and Hemorrhagic Episodes after Surgical Heart Valve Replacement

Introduction: Although, the effects of patient education on the effective anticoagulant management, among patients undergoing heart valve replacement with a mechanical prosthesis, have been reported, the evidence of this association remains inconclusive. Aim: To investigate the effect of a nurse-led patient education program for oral anticoagulant therapy on the incidence of thromboembolic and ...

متن کامل

Pregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves

There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...

متن کامل

Optimal oral anticoagulant therapy in patients with mechanical heart valves.

BACKGROUND The optimal intensity of oral anticoagulant therapy for patients with mechanical heart valves (i.e., the level at which thromboembolic complications are effectively prevented without excessive bleeding) is not known. We attempted to determine the optimal intensity by calculating the incidence of both complications at different levels of anticoagulation. METHODS Data were collected ...

متن کامل

Thromboembolic complications of prosthetic cardiac valves.

Our experience with thromboembolism in 283 patients surviving at least 1 week following insertion of Starr-Edwards valves is reported here. Of these patients, 155 underwent aortic valve replacement, 21 had aortic valve replacement with mitral commissurotomy, 80 had mitral replacement, and 27 had both aortic and mitral valve replacement. Complete follow-up data were obtained on all patients, fro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The heart surgery forum

دوره 13 2  شماره 

صفحات  -

تاریخ انتشار 2010