Usefulness of dynamic volume scanning with 320-row CT in detecting recanalization of pulmonary arteriovenous fistula after coil embolization
نویسندگان
چکیده
Pulmonary arteriovenous fistula is a congenital and rarely acquired anomalous direct communications between pulmonary arteries and veins. Transcatheter embolization using metallic coil or detachable balloon is one of the common treatment procedure. However, recanalization after the embolization is one of the concern and its differentiation from the retrograde filling via pulmonary vein is difficult except using invasive angiography. We report a case with recanalized pulmonary arteriovenous fistula non-invasively detected by dynamic CT angiography with 320-rows multi detector CT. A 45-year-old women who had underwent coil embolization for pulmonary arteriovenous fistula was examined with dynamic CT angiography and antegrade contrast enhancement of the fistula was noted. The recanalization through the embolized artery was confirmed by digital subtraction angiography, and the second coil embolization was performed. The follow-up dynamic CT angiography at three months after the second procedure found the retrograde enhancement of aneurysmal sac and no antegrade shunt. The dynamic CT angiography was useful for the detect the recanalization of pulmonary arteriovenous fistula. Delayed pulmonary artery recanalization was reported to be observed in 5- 10% of cases as a complication after the successful occlusion of segmental pulmonary artery. Lack of change in aneurysmal diameter of pulmonary arteriovenous fistula demonstrated by CT was reported as the result of persistent aneurysmal perfusion or aneurysmal thrombosis. However, the retrograde filling of aneurysmal sac via pulmonary vein or remnant collateral pathway to the pulmonary arteriovenous fistula were also considered. Therefore, before the invasive procedure, we performed dynamic CT angiography to detect the flow direction and pathway to the pulmonary arteriovenous fistula. Using dynamic CT angiography, we could obtain hemodynamic information through the aneurysmal sac of pulmonary arteriovenous fistula and decide to proceed to the invasive embolotherapy. Prospective perfusion CT scan could be an alternative to invasive angiography in the initial follow-up after the embolotherapy or in the cases with the recanalization of pulmonary arteriovenous fistula.
منابع مشابه
Ultra-short echo time magnetic resonance imaging for detection of pulmonary arteriovenous malformation recanalization after coil embolization: a case report and a phantom study
A pulmonary arteriovenous malformation (PAVM) is a direct connection between the pulmonary arteries and veins for which metallic coil transcatheter embolization is the standard of care. Detecting recanalization after PAVM treatment is crucial, but direct visualization with computed tomography or magnetic resonance imaging (MRI) is generally difficult. Here, we report a case of a recanalized PAV...
متن کاملUsefulness of dynamic renal scintigraphy in a patient with renal arteriovenous fistula treated by transcatheter embolization.
Tc-99m-DTPA renal scintigraphy was performed before and after transcatheter coil embolization in a patient with renal arteriovenous fistula (AVF). Before embolization, scintigraphy showed a characteristic accumulation pattern compatible with the hemodynamics of an aneurysmal type of AVF in the vascular phase. After embolization, the effects of treatment, such as a change in the split renal func...
متن کاملTranscatheter coil embolization for coronary and pulmonary arteriovenous malformations
C oronary artery fistulas (CAFs) and pulmonary arteriovenous malformations (PAVMs) are relatively rare but clinically important cardiovascular abnormalities that may require percutaneous treatment. In most patients, the current preferred treatment for both lesions is transcatheter embolization using techniques that are well established in these two conditions. We present a review of CAF and PAV...
متن کاملTime-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms
BACKGROUND Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, CT examination is susceptible to coil artifacts, which sometimes makes it difficult to assess recanalization. We report 2 cases where recanalization was successfully visualized using time-resolved magnetic resonance angiography after coil embolization of visceral...
متن کاملUsefulness of C-stopper Coil for Neurointervention
C-stopper coil (CSC) which are available for 0.018-inch inner diameter microcenter have been used for neurointervention such as transarterial embolization (TAE) of feeding artery. Although various shapes of pushable microcoils have been developed, microcoils are usually short to embolize the lesion and require lots of coils. The most specific feature of CSC is the extended length of 18 cm. To e...
متن کامل