Does b1000-b0 Mismatch Challenge Diffusion-Weighted Imaging-Fluid Attenuated Inversion Recovery Mismatch in Stroke?

نویسندگان

  • Ana Filipa Geraldo
  • Lise-Prune Berner
  • Julie Haesebaert
  • Aurélie Chabrol
  • Tae-Hee Cho
  • Laurent Derex
  • Marc Hermier
  • Guy Louis-Tisserand
  • Leila Chamard
  • Irene Klaerke Mikkelsen
  • Lars Ribe
  • Leif Østergaard
  • Niels Hjort
  • Salvador Pedraza
  • Götz Thomalla
  • Jean-Claude Baron
  • Norbert Nighoghossian
  • Yves Berthèzene
چکیده

BACKGROUND AND PURPOSE Our aim was to explore whether the mismatch in lesion visibility between b1000 and b0 images is an alternative to mismatch between diffusion-weighted imaging and fluid-attenuated inversion recovery imaging as a surrogate marker of stroke age. METHODS We analyzed patients from the European multicenter I-KNOW database. Independent readers assessed the visibility of ischemic lesions of the anterior circulation on b0 and fluid-attenuated inversion recovery imaging images. The signal-intensity ratio for b0 and fluid-attenuated inversion recovery imaging images was also measured from the segmented stroke lesion volume on b1000 images. RESULTS This study included 112 patients (68 men; mean age, 67.4 years) with stroke onset within (n=85) or longer than (n=27) 4.5 hours. b1000-b0 mismatch identified patients within 4.5 hours of stroke onset with moderate sensitivity (72.9%; 95% confidence interval [CI], 63.5-82.4) and specificity (70.4%; 95% CI, 53.2-87.6), high positive predictive value (88.6%; 95% CI, 81.1-96.0), and low negative predictive value (45.2%; 95% CI, 30.2-60.3). Global comparison of b1000-b0 mismatch with diffusion-weighted imaging-fluid-attenuated inversion recovery imaging mismatch (considered the imaging gold standard) indicated high sensitivity (85.9%; 95% CI, 78.2-93.6), specificity (91.2%; 95% CI, 76.3-98.1), and positive predictive value (96.7%; 95% CI, 88.0-99.1) and moderate negative predictive value (73.8%; 95% CI, 60.5-87.1) of this new approach. b0 signal-intensity ratio (r=0.251; 95% CI, 0.069-0.417; P=0.008) was significantly although weakly correlated with delay between stroke onset and magnetic resonance imaging. CONCLUSIONS b1000-b0 mismatch may identify patients with ischemic stroke of the within 4.5 hours of onset with high positive predictive value, perhaps constituting an alternative imaging tissue clock.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perfusion MR predicts outcome in high-risk transient ischemic attack/minor stroke: a derivation-validation study.

BACKGROUND AND PURPOSE Transient or minor ischemic stroke is associated with an early risk of deterioration. Baseline perfusion-diffusion mismatch may predict clinical deterioration and infarct growth in this population. METHODS High-risk transient ischemic attack and minor stroke (National Institutes of Health Stroke Scale ≤3) subjects were prospectively enrolled and imaged with MRI within 2...

متن کامل

Color-coded fluid-attenuated inversion recovery images improve inter-rater reliability of fluid-attenuated inversion recovery signal changes within acute diffusion-weighted image lesions.

BACKGROUND AND PURPOSE Diffusion-weighted image fluid-attenuated inversion recovery (FLAIR) mismatch has been considered to represent ischemic lesion age. However, the inter-rater agreement of diffusion-weighted image FLAIR mismatch is low. We hypothesized that color-coded images would increase its inter-rater agreement. METHODS Patients with ischemic stroke <24 hours of a clear onset were re...

متن کامل

Prediction of Stroke Onset Is Improved by Relative Fluid-Attenuated Inversion Recovery and Perfusion Imaging Compared to the Visual Diffusion-Weighted Imaging/Fluid-Attenuated Inversion Recovery Mismatch.

BACKGROUND AND PURPOSE Acute stroke patients with unknown time of symptom onset are ineligible for thrombolysis. The diffusion-weighted imaging and fluid-attenuated inversion recovery (FLAIR) mismatch is a reasonable predictor of stroke within 4.5 hours of symptom onset, and its clinical usefulness in selecting patients for thrombolysis is currently being investigated. The accuracy of the visua...

متن کامل

Fluid-Attenuated Inversion Recovery Vascular Hyperintensities-Diffusion-Weighted Imaging Mismatch Identifies Acute Stroke Patients Most Likely to Benefit From Recanalization.

BACKGROUND AND PURPOSE Fluid-attenuated inversion recovery vascular hyperintensities (FVH) beyond the boundaries of diffusion-weighted imaging (DWI) lesion (FVH-DWI mismatch) have been proposed as an alternative to perfusion-weighted imaging (PWI)-DWI mismatch. We aimed to establish whether FVH-DWI mismatch can identify patients most likely to benefit from recanalization. METHODS FVH-DWI mism...

متن کامل

Fluid-attenuated inversion recovery and diffusion- and perfusion-weighted MRI abnormalities in 117 consecutive patients with stroke symptoms.

BACKGROUND AND PURPOSE Diffusion-weighted MRI (DWI) is highly sensitive to early cerebral ischemia, but its dependence on lesion location, acuity, and etiology remains unknown. Furthermore, although a marked perfusion-weighted MRI (PWI)-DWI mismatch may exist in a subset of acute strokes, the frequency and distribution of these mismatches have never been methodically characterized in an unselec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2016