Intraventricular early diastolic filling during acute myocardial ischemia, assessment by multigated color m-mode Doppler echocardiography.

نویسندگان

  • M Stugaard
  • O A Smiseth
  • C Risöe
  • H Ihlen
چکیده

BACKGROUND Color M-mode Doppler echocardiography has been suggested as a new noninvasive technique for assessing left ventricular diastolic function. The present study investigated intraventricular filling pattern by color M-mode Doppler in patients during percutaneous transluminal coronary angioplasty (PTCA). In a dog model of myocardial ischemia, the color M-mode flow pattern was related to indices of global and regional myocardial function. METHODS AND RESULTS From color M-mode images, the time difference (TD) between occurrence of peak velocity in the apical region and at the mitral tip was determined in 20 patients and eight anesthetized dogs during coronary occlusions. During PTCA, the timing of peak velocity was progressively delayed from mitral valve to apex. Consistent with this, the dog model showed delayed apical filling during coronary occlusion; TD increased from 18 +/- 4 to 71 +/- 9 milliseconds (P < .01). In the ischemic region, systolic shortening (sonomicrometry) decreased from 20 +/- 3% to -5 +/- 2% (p < .01). The one-third filling fraction decreased from 59 +/- 5% to 31 +/- 6% (P < .01) and correlated with TD (r = .85, P < .01). The time constant of isovolumic relaxation (tau) increased slightly and correlated with TD (r = .81, P < .01). Pacing tachycardia, caval constriction, and volume loading were performed to mimic the ischemia-induced changes in heart rate, stroke volume, and intracavitary filling pressure, respectively. There were no significant changes in TD or tau during these interventions. CONCLUSIONS Color M-mode Doppler echocardiography showed a marked delay of apical peak filling velocity during PTCA. The experimental data suggest that this reflects retarded filling of the ischemic ventricle. Thus, color M-mode Doppler may provide a useful method for assessing diastolic dysfunction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Paclitaxel-coated stent: is there a light at the end of the tunnel?

1. Firstenberg MS, Vandervoort PM, Greenberg NL, et al. Noninvasive estimation of transmitral pressure drop across the normal mitral valve in humans: importance of convective and inertial forces during left ventricular filling. J Am Coll Cardiol 2000;36:1942–9. 2. Beppu S, Izumi S, Miyatake K, et al. Abnormal blood pathways in left ventricular cavity in acute myocardial infarction. Experimental...

متن کامل

Diastolic Function and Dysfunction the Echo-doppler Evaluation of Left Ventricular Diastolic Function

7. Appleton CP, Hatle LK: The natural history of left ventricular filling abnormalities: Assessment by two-dimensional and Doppler echocardiography. Echocardiography 9:437-457, 1992 8. Appleton CP, Hatle LK, Popp RL: Cardiac tamponade and pericardial effusion: Respiratory variation in transvalvular flow velocities studied by Doppler echocardiography. J Am Coll Cardiol 11:1020-1030, 1988 Abstrac...

متن کامل

Mechanisms of retarded apical filling in acute ischemic left ventricular failure.

BACKGROUND We examined the hypothesis that retardation of apical filling as measured by color M-mode Doppler echocardiography in the diseased left ventricle (LV) reflects a decrease in the intraventricular mitral-to-apical pressure gradient. METHODS AND RESULTS In 9 open-chest anesthetized dogs, micromanometers were placed near the mitral tip and in the apical region. From the color M-mode Do...

متن کامل

Postsystolic shortening of ischemic myocardium: a mechanism of abnormal intraventricular filling.

Acute myocardial ischemia has been associated with abnormal filling patterns in the left ventricular (LV) apex. We hypothesized that this may in part be due to postsystolic shortening of ischemic apical segments, which leads to reversal of early diastolic apical flow. Fourteen open-chest anesthetized dogs were instrumented with micromanometers in the LV apex and left atrium and myocardial sonom...

متن کامل

Alternations in Intraventricular Filling Pattern by Color Doppler M-mode during Induced Myocardial Ischemia

It has been shown that regional myocardial ischemia during angioplasty is associated with retarded apical filling. To test the importance of retarded apical filling by color Doppler M-mode to detect ischemia during dipyridamole (DIP)stress echo we evaluated 29 patients (pts) (12 females, age 57±87 years).The high dose DIP (0.84 mg/kg over 10 min) was used. The color M mode record was used to ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 88 6  شماره 

صفحات  -

تاریخ انتشار 1993