DOI: 10.5935/abc.20140157 A 43-year-o ld male pat ient presented wi th a complaint of palpitation. Electrocardiography revealed premature ventricular contraction (PVC) that appeared to be originating from the left ventricular outflow tract. Tall positive R waves were observed in leads II, III, and aVF, and the R transition was observed at V2 in precordial leads. A notch was realized on the downward deflection of QS, which was only at lead V1. (Figure 1) This finding indicates that the region between the right and left coronary commissures is the origin of VPS. In addition, 24-h Holter monitoring revealed 32000 PVCs. Therefore, an electrophysiology study was planned. During the procedure, the catheter was moved between the right coronary and left coronary commissures, and the ablation catheter was placed at the ventricular side of the commissures where the earliest signal recorded was at 40 ms. At this site, pacing produced 12/12 morphology with PVC. In addition, at this site, we demonstrated a deflection prior to the intracardiac ventricular electrogram of PVCs corresponding to the notch. This deflection was after the intracardiac ventricular electrogram during sinus beats (Figure 1). Ablation was performed at 20 watt 45 degrees, and it terminated all PVCs at this site.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

یافته‌های الکتروکاردیوگرام در تاکی‌کاردی بطنی با منشا خروجی بطن راست و بطن چپ

Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes ms...

متن کامل

Radiofrequency ablation of ventricular premature contraction originating from a native coronary cusp after transcatheter aortic valve replacement

We describe a case of radiofrequency ablation of ventricular premature contraction (VPC) originating from the left ventricular outflow tract after transcatheter aortic valve replacement. The VPC origin was the native aortic valve annulus between the left and right coronary cusps. Radiofrequency ablation was successfully performed by manipulating the ablation catheter from the gap between the si...

متن کامل

Localization of premature ventricular contraction foci in normal individuals based on multichannel electrocardiogram signals processing

A premature ventricular contraction (PVC) is relatively a common event where the heartbeat is initiated by the other pathway rather than by the Sinoatrial node, the normal heartbeat initiator. Determining PVC foci is important for ablation procedure and it can help in pre-procedural planning and potentially may improve ablation outcome. In this study, 12-lead Electrocardiogram (ECG) of 87 patie...

متن کامل

A new mapping method to estimate exit sites of ventricular arrhythmias using intracardiac echocardiography and M-mode for catheter ablation

BACKGROUND Catheter ablation of premature ventricular complexes (PVCs) has been used as a curative therapy in many cases. Intracardiac ultrasound with a magnetic sensor probe has recently become available for catheter ablation. In this study, we assessed a new mapping method, contraction mapping, for determining the optimal ablation sites using intracardiac ultrasound and M-mode. This study sou...

متن کامل

Detection and Classification of Heart Premature Contractions via α-Level Binary Neyman-Pearson Radius Test: A Comparative Study

The aim of this study is to introduce a new methodology for isolation of ectopic rhythms of ambulatory electrocardiogram (ECG) holter data via appropriate statistical analyses imposing reasonable computational burden. First, the events of the ECG signal are detected and delineated using a robust wavelet-based algorithm. Then, using Binary Neyman-Pearson Radius test, an appropriate classifie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 103  شماره 

صفحات  -

تاریخ انتشار 2014