The effect of electromagnetic guidance system on early learning curve of ultrasound for novices

نویسندگان

  • Eun Jung Kim
  • Jiyoung Min
  • Jeongyun Song
  • Kyungchul Song
  • Jang-Ho Song
  • Hyo Jin Byon
چکیده

BACKGROUND Electromagnetic guidance reveals needle alignment and position relative to the image plane on an ultrasound view. This study compared the early learning curves of novices performing ultrasound-guided needle placement with (n = 10) or without electromagnetic guidance (n = 10). METHODS Participants performed 30 ultrasound-guided needle placements using an echogenic stick (0.3-cm diameter) as a target inside a phantom model; this early learning period was divided into sequential periods (P1: 1-5, P2: 6-10, P3: 11-15, P4: 16-20, P5: 21-25, P6: 26-30 attempts). RESULTS Using an in-plane approach, the time required for needle placement in the EMG group was significantly shorter than that of the non-EMG group in P1, P2, P4, and P6 and the number of needle advances of the EMG group was significantly smaller than that of the non-EMG group in P1 and P2. Using an out-of-plane approaches, the time required for needle placement in the EMG group was significantly shorter than that of the non-EMG group in all periods, but the number of needle advances was similar between both groups in P1-P5. CONCLUSIONS The electromagnetic guidance system may be beneficial when performing ultrasound guided peripheral nerve blocks or vascular cannulation in the early learning period, especially by inexperienced operators with reducing patient risk.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel 3-D laparoscopic magnetic ultrasound image guidance for lesion targeting.

OBJECTIVES Accurate laparoscopic liver lesion targeting for biopsy or ablation depends on the ability to merge laparoscopic and ultrasound images with proprioceptive instrument positioning, a skill that can be acquired only through extensive experience. The aim of this study was to determine whether using magnetic positional tracking to provide three-dimensional, real-time guidance improves acc...

متن کامل

Different Learning Curves for Axillary Brachial Plexus Block: Ultrasound Guidance versus Nerve Stimulation

Little is known about the learning of the skills needed to perform ultrasound- or nerve stimulator-guided peripheral nerve blocks. The aim of this study was to compare the learning curves of residents trained in ultrasound guidance versus residents trained in nerve stimulation for axillary brachial plexus block. Ten residents with no previous experience with using ultrasound received ultrasound...

متن کامل

Comparison of static and electromagnetic field effects on redox system of soybean seedlings

The effects of magnetic fields (MF) on germination and early growth parameters, redox state and the activity of antioxidant system were investigated in soybean (Glycine max L. Merrill) seedlings. The seeds were imbibed in water and then were exposed to a 30 mT static magnetic field (SMF) and a 10 kHz electromagnetic field (EMF) for 4 days, each 5 h. Water uptake of seeds increased after 40 and ...

متن کامل

Successful novice's training in obtaining accurate assessment of carotid IMT using an automated ultrasound system.

AIMS The aim of this study was to assess the feasibility and learning curve of training novice operators in using automated ultrasound to achieve satisfactory carotid intima-media thickness (CIMT) measurements. METHODS AND RESULTS Four novices underwent 4 weeks carotid ultrasound training using a newly developed automated ultrasonograph. A longitudinal B-mode image of the distal right common ...

متن کامل

Sensitivity, specificity and diagnostic accuracy of novices integrating lung ultrasound into the care of breathless older patients

Background: Lung ultrasound is frequently used to identify pulmonary oedema, using the 'B line' artefact. A small study in 2011 suggested that novice sonologists had a potential diagnostic accuracy of 85%, when performing the test without reference to other patient information. Aim: We aimed to test the overall diagnostic accuracy of novice clinician sonologists incorporating the 2011 protocol ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 69  شماره 

صفحات  -

تاریخ انتشار 2016