Echocardiography and Hemodynamic Monitoring Tools for Clinical Assessment of Patients on Mechanical Circulatory Support

نویسندگان

  • Sabino Scolletta
  • Bonizella Biagioli
  • Federico Franchi
  • Luigi Muzzi
چکیده

Echocardiography is considered as the procedure of choice for the evaluation of cardiac performance and to gather other critical information both in the pre, intra and postoperative phases. Also, echo-Doppler-based methods can be used to calculate the flow velocity and volume and hence systemic blood flow. Unfortunately, due to intrinsic nature, echocardiog‐ raphy cannot be considered a bedside continuous monitoring system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic Transesophageal Echocardiography-Guided Venous-Arterial Extracorporeal Membrane Oxygenation Support in a Case of Giant Cell Myocarditis

Giant cell myocarditis (GCM) is a rare and commonly fatal form of fulminant myocarditis. During the acute phase, while immunosuppressive therapy is initiated, venoarterial extracorporeal membrane oxygenation (VA-ECMO) support is commonly used as a bridge to heart transplantation or recovery. Until recently, conventional transesophageal echocardiography and transthoracic echocardiography were th...

متن کامل

Evaluation of Cardiac Function in Patients with Brain Death using Advanced Hemodynamic Monitoring

Background: Studies on hemodynamic changes in brain death are in vitro and in animal studies. And very few studies have been done on the hemodynamic changes of brain death. The aim of this study was to use advanced hemodynamic monitoring with echocardiography for evaluation of donated heart and to evaluate the moment by moment brain death patients with advanced hemodynamic monitoring tools and ...

متن کامل

مانیتورینگ همودینامیک به روش غیر تهاجمی در بخش مراقبت های ویژه: مقاله مروری

Aim and background : Hemodynamic monitoring of critical patients in intensive units is the cornstone of care. It constitutes an extensive part of care and is helpful in determination of the causes and the response to treatment of hemodynamic instability. Aim of this review articale is to investigate of the Non invasive hemodynamic monitoring in critical care units. Materials and Methods:61 art...

متن کامل

Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit

PURPOSE Stroke volume (SV) is a parameter that is being recognized as an endpoint in fluid resuscitation algorithms. Its role is now being realized as an important variable in hemodynamic assessment in various clinical scenarios such as septic and cardiogenic shocks. Direct measurement of stroke volume (SV) and its novel corollary, stroke volume variation (SVV) derived by proprietary software, ...

متن کامل

Echocardiographic Evaluation of Hemodynamics in Neonates and Children

Hemodynamic instability and inadequate cardiac performance are common in critically ill children. The clinical assessment of hemodynamic status is reliant upon physical examination supported by the clinical signs such as heart rate, blood pressure, capillary refill time, and measurement of the urine output and serum lactate. Unfortunately, all of these parameters are surrogate markers of cardio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013