Thrombogenicity of heparin- and non-heparin-coated catheters: clinical trail.
نویسندگان
چکیده
Catheters used in clinical cerebral angiography were examined by scanning electron microscopy for buildup of thrombus. In 21 (67%) of 31 individuals studied with non-heparin-coated catheters, either cell aggregations or thrombi developed compared with seven (28%) of 25 individuals studied with heparin-coated catheters. The median size of the cell aggregations and thrombi on non-heparin- and heparin-coated catheters was significantly different (p less than 0.01). The slopes that estimated the probable rate of thrombus formation were also significantly different (p less than 0.01). This suggests the desirability of replacement of non-heparin-coated catheters if the angiographic procedure is extended.
منابع مشابه
Thrombocytopenia associated with heparin-coated catheters in patients with heparin-associated antiplatelet antibodies.
Thrombocytopenia was associated with the presence of heparin-coated pulmonary artery catheters in 12 patients with heparin-associated antiplatelet antibodies. The thrombocytopenia persisted so long as the heparin-coated catheters were in place, even when all other sources of heparin were discontinued. The high morbidity and mortality associated with heparin-induced thrombocytopenia mandates tha...
متن کاملDoes heparin coating improve patency or reduce infection of tunneled dialysis catheters?
BACKGROUND AND OBJECTIVES Tunneled dialysis catheters are prone to frequent malfunction and infection. Catheter thrombosis occurs despite prophylactic anticoagulant locks. Catheter thrombi may also serve as a nidus for catheter infection, thereby increasing the risk of bacteremia. Thus, heparin coating of catheters may reduce thrombosis and infection. This study evaluated whether heparin-coated...
متن کاملHeparin Resistance During and Post-Intravenous Nitroglycerin Infusion
Nitroglycerin has been reported to reduce activated partial thromboplastin time (aPTT) values in patients treated with concurrent heparin and nitroglycerin. However, studies have yielded conflicting results. To determine whether intravenous nitroglycerin alters the anticoagulant effect of heparin, we prospectively evaluated twenty patients admitted for coronary angioplasty by measurin...
متن کاملImparting electroactivity to polycaprolactone fibers with heparin-doped polypyrrole: Modulation of hemocompatibility and inflammatory responses.
Hemocompatibility, anti-inflammation and anti-thrombogenicity of acellular synthetic vascular grafts remains a challenge in biomaterials design. Using electrospun polycaprolactone (PCL) fibers as a template, a coating of polypyrrole (PPy) was successfully polymerized onto the fiber surface. The fibers coated with heparin-doped PPy (PPy-HEP) demonstrated better electroactivity, lower surface res...
متن کاملPreclinical evaluation of the thrombogenicity and endothelialization of bare metal and surface-coated neurovascular stents.
BACKGROUND AND PURPOSE Stent-assisted coiling is routinely used for the endovascular treatment of complex or wide-neck intracranial aneurysms. However, in-stent thrombosis, thromboembolic events, and ischemic complications remain a major concern associated with stent implants. Therefore, a novel low-profile neurovascular stent with a bare metal surface was investigated with regard to thrombogen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJR. American journal of roentgenology
دوره 139 5 شماره
صفحات -
تاریخ انتشار 1982