A-1981A: Stem Cell Analyses Using the Vi-CELLTM XR
ثبت نشده
چکیده
Stem cells, which resemble white blood cells with very small nuclei and cytoplasm, have the capacity to differentiate into any of the mature blood cells. Very primitive, pleuripotent stem cells have the capability of differentiation into other cell types, such as heart and nerve, as well. Since 1968, stem cells in bone marrow have been used in treatment of leukemias, lymphomas, and immune deficiency disorders. More recently, cord blood and peripheral blood stem cells have been utilized. Currently, the main sources for stem cells are bone marrow, cord blood, and peripheral blood. Chemotherapy and radiation used in cancer therapy have an adverse effect on bone marrow. Stem cells have been used to repopulate a patient’s bone marrow subsequent to high-dose chemotherapy or radiation treatments. The choice of the source of stem cells is often based on such factors as the health of the bone marrow cells or the difficulty of stem cell collection. For example, harvesting stem cells from the bone marrow may require general anesthesia. Peripheral blood stem cells are collected, over several days, by the apheresis process. Also, if the patient’s bone marrow contains cancerous cells, sometimes healthy cells may be obtained from peripheral blood. Often the stem cells, regardless of source, are frozen for future cellular transplantation. Upon thawing, these cells must be assayed for both percentage viability and concentration. Many facilities employ the manual, trypan blue method for these measurements. The Beckman Coulter Vi-CELL XR (Figure 1) automates the manual trypan blue vital dye cell viability method. The instrument removes the subjective variation among operators inherent in manual cell enumeration using a microscope. This Application Bulletin demonstrates that stem cell percentage viability and concentration, from the above-mentioned sources, may be measured accurately and precisely using the Beckman Coulter Vi-CELL XR.
منابع مشابه
Validation Study of the Vi-CELLTM XR for Automated Cell Counting of Dendritic Cells
Dendritic cells (DC) population is a key functional constituent of cell based immunotherapy drugs. The correct cell count and adequate viability of DC are one of the quality control criteria for the final product release. Number of viable DC is historically determined by microscopy using manual counting method – Bürker chamber and trypan blue dye for dead cell exclusion. The manual method can h...
متن کاملProduction and functional characterization of human insulin-like growth factor 1
Insulin-like growth factor 1 (IGF-1) is a polypeptide hormone produced mainly by the liver in response to the endocrine growth hormone (GH) stimulus. This protein is involved in a wide range of cellular functions, including cellular differentiation, transformation, apoptosis suppression, migration and cell-cycle progression and other metabolic processes. In the current study, human heart cDNA w...
متن کاملEvaluation of an automated instrument for viability and concentration measurements of cryopreserved hematopoietic cells.
Two important parameters for determination of deleterious effects of cellular processing on hematopoietic progenitor cells are cell viability and concentration. The Sidney Kimmel Comprehensive Cancer Center at Johns Hopkins Hospital evaluated the Beckman Coulter Vi-Cell automated instrument for the measurement of these two parameters. Using 33 thawed hematopoietic progenitor cell samples, autom...
متن کاملComparison of Transplantation of Bone Marrow Stromal Cells (BMSC) and Stem Cell Mobilization by Granulocyte Colony Stimulating Factor after Traumatic Brain Injury in Rat
Background: Recent clinical studies of treating traumatic brain injury (TBI) with autologous adult stem cells led us to compare effect of intravenous injection of bone marrow mesenchymal stem cells (BMSC) and bone marrow hematopoietic stem cell mobilization, induced by granulocyte colony stimulating factor (G-CSF), in rats with a cortical compact device. Methods: Forty adult male Wistar rats w...
متن کاملDetermining rectal dose through cervix cancer radiotherapy by 9 MV photon beam using TLD and XR type T GAFCHROMIC® Film
Background: The goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. Materials and Methods: The study was carried out using a Nepton 10...
متن کامل