Volar locking distal radius plates show better short-term results than other treatment options: A prospective randomised controlled trial
نویسندگان
چکیده
AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation. METHODS A prospective, randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomised to treatment either with a volar locking plate (n = 29), or another treatment modality (n = 27; cast immobilisation with or without wires or external fixator). Outcomes were measured at 12 wk. Functional outcome scores measured were the Patient-Rated Wrist Evaluation (PRWE) Score; Disabilities of the Arm, Shoulder and Hand and activities of daily living (ADLs). Clinical outcomes were wrist range of motion and grip strength. Radiographic parameters were volar inclination and ulnar variance. RESULTS Patients in the volar locking plate group had significantly better PRWE scores, ADL scores, grip strength and range of extension at three months compared with the control group. All radiological parameters were significantly better in the volar locking plate group at 3 mo. CONCLUSION The present study suggests that volar locking plates produced significantly better functional and clinical outcomes at 3 mo compared with other treatment modalities. Anatomical reduction was significantly more likely to be preserved in the plating group. Level of evidence: II.
منابع مشابه
Stainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial
BACKGROUND Distal radius fractures are among the most common fractures seen in the hospital emergency department. Of these, over 40% are considered unstable and require some form of fixation. In recent years with the advent of low profile plating, open reduction and internal fixation (ORIF) using volar plates has become the surgical treatment of choice in many hospitals. However, it is currentl...
متن کاملDistal radius measurements and efficacy of fixed-angle locking volar plates.
AIM For surgical treatment of unstable distal radius fractures, fixed-angled locking volar plate fixation is becoming popular nowadays because of some advantages over other surgical techniques. In this article, we discuss the fitting of fixed-angle locking volar plates to the distal radius in relation to the changes in the distal radial angles. MATERIALS AND METHODS First, we took conventiona...
متن کاملPercutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial
OBJECTIVES To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. DESIGN A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. SETTING 18 trauma centres in the United Kingdom. PARTICIPANTS 461 adults with a dorsally displaced ...
متن کاملVolar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis
Objective: The superiority of volar locking plate fixation and K-wire fixation on treatment of distal radius fractures was controversial. Thus, we performed a meta-analysis to compare the efficacy of volar locking plate and K-wires for distal radius fracture. Methods: We searched Embase, Medline and PubMed for randomized controlled trials which compare the effects of volar locking plate and K-w...
متن کاملSurgery versus conservative treatment in patients with type A distal radius fractures, a randomized controlled trial
BACKGROUND Fractures of the distal radius are common and account for an estimated 17% of all fractures diagnosed. Two-thirds of these fractures are displaced and require reduction. Although distal radius fractures, especially extra-articular fractures, are considered to be relatively harmless, inadequate treatment may result in impaired function of the wrist. Initial treatment according to Dutc...
متن کامل