Artifacts associated with implementation of the Grangeat formula.

نویسندگان

  • Seung Wook Lee
  • Gyuseong Cho
  • Ge Wang
چکیده

To compensate for image artifacts introduced in approximate cone-beam reconstruction, exact cone-beam reconstruction algorithms are being developed for medical x-ray CT. Although the exact cone-beam approach is theoretically error-free, it is subject to image artifacts due to the discrete nature of numerical implementation. We report a study on image artifacts associated with the Grangeat algorithm as applied to a circular scanning locus. Three types of artifacts are found, which are thorn, wrinkle, and V-shaped artifacts. The thorn pattern is created by inappropriate extrapolation into the shadow zone in the radon domain. If the shadow zone is filled in with continuous data, the thorn artifacts along the boundary of the shadow zone can be removed. The wrinkle appearance arises if interpolated first derivatives of the radon data are not smooth between adjacent detector planes. In particular, the nearest-neighbor interpolation method should not be used. If the number of projections is not small, the bilinear interpolation method is effective to suppress the wrinkle artifacts. The V-shaped artifacts on the meridian plane come from the line integrations through the transition zones where derivative data change abruptly. Two remedies are to increase the sampling rate and suppress data noise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Grangeat-type half-scan algorithm for cone-beam CT.

Modern CT and micro-CT scanners are rapidly moving from fan-beam toward cone-beam geometry. Half-scan CT algorithms are advantageous in terms of temporal resolution, and widely used in fan-beam and cone-beam geometry. While existing half-scan algorithms for cone-beam CT are in the Feldkamp framework, in this paper we compensate missing data explicitly in the Grangeat framework, and formulate a ...

متن کامل

Grangeat-type helical half-scan computerized tomography algorithm for reconstruction of a short object.

Currently, cone-beam computerized tomography (CT) and micro-CT scanners are under rapid development for major biomedical applications. Half-scan cone-beam image reconstruction algorithms assume only part of a scanning turn, and are advantageous in terms of temporal resolution and image artifacts. While the existing half-scan cone-beam algorithms are in the Feldkamp framework, we have published ...

متن کامل

Analysis of Cone-Beam Artifacts in off-Centered Circular CT for Four Reconstruction Methods

Cone-beam (CB) acquisition is increasingly used for truly three-dimensional X-ray computerized tomography (CT). However, tomographic reconstruction from data collected along a circular trajectory with the popular Feldkamp algorithm is known to produce the so-called CB artifacts. These artifacts result from the incompleteness of the source trajectory and the resulting missing data in the Radon s...

متن کامل

The Formula of Grangeat for Tensor Fields of Arbitrary Order in n Dimensions

The cone beam transform of a tensor field of order m in n >/= 2 dimensions is considered. We prove that the image of a tensor field under this transform is related to a derivative of the n-dimensional Radon transform applied to a projection of the tensor field. Actually the relation we show reduces for m = 0 and n = 3 to the well-known formula of Grangeat. In that sense, the paper contains a ge...

متن کامل

Evaluation of Artifacts in Oral and Maxillofacial Histopathological Slides

Introdouction: One of the reasons that cause a pathologist to make an incorrect diagnosis includes artifacts leading to tissue changes and artificial structures in microscopic slides. The aim of this study was to examine the artifacts in histopathological slides in Zahedan School of Dentistry. Materials and methods: In this cross-sectional study, all the available slides in Oral and Maxil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 29 12  شماره 

صفحات  -

تاریخ انتشار 2002