Cholinesterases and the resistance of the mouse diaphragm to the effect of tubocurarine.
نویسندگان
چکیده
BACKGROUND The diaphragm is resistant to competitive neuromuscular blocking agents. Because of the competitive mechanism of action of tubocurarine, the rate of hydrolysis of acetylcholine at the neuromuscular junction may modulate its neuromuscular blocking effect. The authors compared the neuromuscular blocking effect of tubocurarine on isolated diaphragm and extensor digitorum longus (EDL) muscles and quantified the acetylcholinesterase activity in hetero-oligomers. METHODS Adult Swiss-Webster and collagen Q-deficient (ColQ) mice were used. The blocking effect of tubocurarine on nerve-evoked muscle twitches was determined in isolated diaphragm and EDL muscles, after inhibition of acetylcholinesterase by fasciculin-1, butyrylcholinesterase by tetraisopropylpyro-phosphoramide, or both acetylcholinesterase and butyrylcholinesterase by neostigmine, and in acetylcholinesterase-deficient ColQ muscles. The different acetylcholinesterase oligomers extracted from diaphragm and EDL muscles were quantified in sucrose gradient. RESULTS The EC50 for tubocurarine to decrease the nerve-evoked twitch response was four times higher in the diaphragm than in the EDL. The activity of the different acetylcholinesterase oligomers was lower in the diaphragm as compared with the EDL. Inhibition of acetylcholinesterase by antagonists resulted in an increased dose of tubocurarine but an unchanged resistance ratio between the diaphragm and the EDL. A similar diaphragmatic resistance was found in ColQ muscles. CONCLUSION The current study indicates that, despite differences in acetylcholinesterase activity between the diaphragm and EDL, the diaphragmatic resistance to tubocurarine cannot be explained by the different rate of acetylcholine hydrolysis in the synaptic cleft.
منابع مشابه
Influence of Quantal Transmitter Release and Nicotinic Acetylcholine Receptors
Background: The diaphragm is resistant to competitive neuromuscular blocking agents, as compared to peripheral muscles. The basis of this difference may be a higher concentration of acetylcholine released or higher number of postsynaptic nicotinic acetylcholine receptors in diaphragmatic neuromuscular junctions. Methods: Nerve-evoked twitch-tension was measured in rat hemidiapragm as was Extens...
متن کاملThe Effect of Corrugations on Mechanical Sensitivity of Diaphragm for MEMS Capacitive Microphone
In this paper the effect of corrugated diaphragm on performance of MEMS microphone is described. The corrugated diaphragm is modeled in order to improve the sensitivity of micromachined silicon acoustic sensor. Analytical analyzes have been carried out to derive mathematic expressions for the mechanical sensitivity and displacement of corrugated diaphragm with residual stress. It is shown that ...
متن کاملRelationships between block-of-twitch and train-of-four fade in the mouse phrenic nerve-diaphragm preparation.
The relationships between the block-of-twitch and train-of-four fade in the presence of nondepolarizing neuromuscular blocking drugs (d-tubocurarine, vecuronium and pancuronium) were examined in vitro by measuring the contractile tension from mouse phrenic nerve-diaphragm preparations. The slope of the block/fade relationship differed between onset of and recovery from neuromuscular block follo...
متن کاملThe effects of Pilates and diaphragm exercises on some pulmonary factors in chronic obstructive pulmonary Patients
Introduction and purpose: Chronic obstructive pulmonary disease (COPD) is one of the most important pulmonary diseases. The most important way to minimize the progress of the disease is to rehabilitate the lung. Rehabilitation of the lung improves respiratory pattern. To this end, the effects of two types of Pilates and Diaphragm exercises on some of the pulmonary factors in these patients were...
متن کاملAccurate Model of Capacitance for MEMS Sensors using Corrugated Diaphragm with Residual Stress
In this paper we present a new model for calculating the capacitance of MEMS sensor with corrugated diaphragm. In this work the effect of residual stress is considered on deflection of diaphragm and capacitance of sensor. First, a new analytical analyzes have been carried out to derive mathematic expressions for central deflection of corrugated diaphragm and its relationship with residual stres...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 103 4 شماره
صفحات -
تاریخ انتشار 2005