Postmortem assay of digoxin by radioimmunoassay.

نویسندگان

  • D W Holt
  • J G Benstead
چکیده

Analysis of postmortem blood samples from patients previously on maintenance digoxin therapy suggests that the results are of value in assessing the degree of digitalization at the time of death. Control cases gave results within the normal therapeutic range wheras of six cases in which digoxin was suspected of being implicated in the death five had 'serum' digoxin levels above the therapeutic range. Differences in digoxin concentration were noted in blood collected from three sites in the body, and it is suggested that postmortem blood should be collected from the leg veins if assessment of antermortem digitalization is to be made.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance assessment of the GammafloTM automated radioimmunoassay system by assaying for digoxin.

We report an evaluation of the GammafloTM automated continuous-flow radioimmunoassay instrument in which we used a digoxin assay to assess system performance. System operation was based on combined continuous-flow and column-chromatographic techniques. No drift or carryover was detectable in 180 within-assay consecutive determinations performed at a rate of 42 determinations per hour (5 h of co...

متن کامل

Postmortem tissue digoxin concentrations in infants and children.

The concentrations of digoxin in tissues of premature infants, full-term infants and older children obtained at autopsy were determined by a radioimmunoassay procedure. Infants were found to have much higher concentrations in the right and left ventricle (about 190 ng/g) than older children (about 70 ng/g) and adults as reported in the literature. Renal concentrations were lower in the prematur...

متن کامل

Measurement of digoxin by radioimmunoassay.

A sensitive, specific and precise procedure for the measurement of digoxin by radioimmunoassay is presented. The method is rapid, convenient and highly reliable for this very important measurement. Studies designed to evaluate the validity and reproducibility of the assay are presented and discussed.

متن کامل

Sensitive radioimmunoassay for digoxin in plasma and urine.

A reproducible and sensitive radioimmunoassay for digoxin in either serum, plasma or urine is described. Using 0.5 ml of serum or plasma, the assay sensitivity is 0.05 ng of digoxin/ml. The antiserum and tracer solutions employed are available in a kit sold in the United States. All other reagents were prepared in the laboratory. The assay allows measurement of digoxin in plasma or serum for 96...

متن کامل

One-hour radioimmunoassay of serum drug concentrations, as exemplified by digoxin and gentamicin.

Double-antibody radioimmunoassays in which tritium is used for labeling have been adapted for emergency determinations of serum drug concentrations. In the cases of digoxin and gentamicin, the first and second antibody incubations may be carried on simultaneously, minimizing incubation times (10 and 27 mm, respectively). Counting the bound radioactivity in solubilized immunospecific precipitate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 1975