Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry.

نویسندگان

  • Jason J Nichols
  • P Ewen King-Smith
چکیده

PURPOSE To evaluate an interferometric method for measuring the thickness of the pre- (PLTF) and postlens tear film (POLTF) in subjects wearing hydrogel contact lenses. The precision and accuracy of measuring postlens tear thickness is compared with a previous method based on optical pachymetry and mechanical measurement of contact lens thickness. METHODS Reflectance spectra (562-1030 nm) from the front of an eye wearing a contact lens were measured at normal incidence. Interference between reflections from four surfaces--the front of the tear film, the front and back of the contact lens, and the front of the cornea--can give rise to as many as six oscillations in the reflectance spectra, three from simple layers (layer A: PLTF; B, POLTF; C, contact lens) and three from composite layers, (layer D, A+C; layer E, C+B; layer F, A+C+B). The thickness of any layer is derived from the frequency of the oscillations. The principle of the method was tested with a rigid contact lens, which was designed to give distinct thicknesses for all six layers. Twenty spectra were then recorded from each of 12 subjects wearing hydrogel contact lenses. RESULTS The PLTF thickness averaged 2.31 microm. There was good agreement between a direct estimate from layer A and an indirect estimate: layer D minus layer C. For POLTF, an indirect estimate--layer F minus layer D--averaged 2.34 microm and was more satisfactory than the direct estimate from layer B. There was no correlation between PLTF and POLTF thickness, showing that these are independent measurements, despite the similarity of their means. CONCLUSIONS Prelens tear thickness was in reasonable agreement with prior measurements. Postlens tear thickness was much less than the 11 to 12 microm found by the pachymetric method. It is argued that the current method avoids some of the systematic errors of the pachymetric method and also has much higher precision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.

PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9...

متن کامل

Noninvasive in vivo assessment of soft contact lens type on tear film surface quality.

PURPOSE To evaluate the effect of soft contact lens type on the in vivo tear film surface quality (TFSQ) on daily disposable lenses and to establish whether two recently developed techniques for noninvasive measurement of TFSQ can distinguish between different contact lens types. METHODS Thirteen subjects wearing four different types of daily soft contact lenses participated in the study. Dyn...

متن کامل

Measurement of post-lens tear thickness.

PURPOSE A method to measure the tear film beneath a soft contact lens, referred to as post-lens tear thickness (PLTT), would have many applications to contact lens research. In this study a noninvasive technique for measuring the PLTT is presented. METHODS The feasibility of measuring the tear layer by optical pachometry was first assessed using a model eye. The baseline corneal thickness (B)...

متن کامل

Association Between Ocular Surface Temperature and Tear Film Stability in Soft Contact Lens Wearers.

Purpose To investigate the correlation between the changes in the ocular surface temperature (OST) and tear film stability over soft contact lenses (SCLs). Methods We enrolled 20 eyes of 20 normal SCL wearers (20 men; 24.4 ± 4.1 years). We used four different daily disposable SCLs: one silicone hydrogel lens (delefilcon A) and three hydrogel lenses (etafilcon A with polyvinylpyrrolidone [PVP]...

متن کامل

Tear film interferometry and corneal surface roughness.

PURPOSE Previous studies of optical interference from the whole thickness of the precorneal tear film showed much lower contrast than from the pre-contact lens tear film. It is hypothesized that the recorded low contrast is related to roughness of the corneal surface compared with the smooth contact lens surface. This hypothesis is tested, and characteristics of this roughness are studied. ME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 44 1  شماره 

صفحات  -

تاریخ انتشار 2003