Force-frequency relationship and potentiation in mammalian skeletal muscle.
نویسندگان
چکیده
Repetitive activation of a skeletal muscle results in potentiation of the twitch contractile response. Incompletely fused tetanic contractions similar to those evoked by voluntary activation may also be potentiated by prior activity. We aimed to investigate the role of stimulation frequency on the enhancement of unfused isometric contractions in rat medial gastrocnemius muscles in situ. Muscles set at optimal length were stimulated via the sciatic nerve with 50-micros duration supramaximal pulses. Trials consisted of 8 s of repetitive trains [5 pulses (quintuplets) 2 times per second or 2 pulses (doublets) 5 times per second] at 20, 40, 50, 60, 70, and 80 Hz. These stimulation frequencies represent a range over which voluntary activation would be expected to occur. When the frequency of stimulation was 20, 50, or 70 Hz, the peak active force (highest tension during a contraction - rest tension) of doublet contractions increased from 2.2 +/- 0.2, 4.1 +/- 0.4, and 4.3 +/- 0.5 to 3.1 +/- 0.3, 5.6 +/- 0.4, and 6.1 +/- 0.7 N, respectively. Corresponding measurements for quintuplet contractions increased from 2.2 +/- 0.2, 6.1 +/- 0.5, and 8.7 +/- 0.7 to 3.2 +/- 0.3, 7.3 +/- 0.6, and 9.0 +/- 0.7 N, respectively. Initial peak active force values were 27 +/- 1 and 61.5 +/- 5% of the maximal (tetanic) force for doublet and quintuplet contractions, respectively, at 80 Hz. With doublets, peak active force increased at all stimulation frequencies. With quintuplets, peak active force increased significantly for frequencies up to 60 Hz. Twitch enhancement at the end of the 8 s of repetitive stimulation was the same regardless of the pattern of stimulation during the 8 s, and twitch peak active force returned to prestimulation values by 5 min. These experiments confirm that activity-dependent potentiation is evident during repeated, incompletely fused tetanic contractions over a broad range of frequencies. This observation suggests that, during voluntary motor unit recruitment, derecruitment or decreased firing frequency would be necessary to achieve a fixed (submaximal) target force during repeated isometric contractions over this time period.
منابع مشابه
Coexistence of potentiation and fatigue in skeletal muscle.
Twitch potentiation and fatigue in skeletal muscle are two conditions in which force production is affected by the stimulation history. Twitch potentiation is the increase in the twitch active force observed after a tetanic contraction or during and following low-frequency stimulation. There is evidence that the mechanism responsible for potentiation is phosphorylation of the regulatory light c...
متن کاملIntramuscular Contributions to Low-Frequency Force Potentiation Induced by a High-Frequency Conditioning Stimulation
Electrically-evoked low-frequency (submaximal) force is increased immediately following high-frequency stimulation in human skeletal muscle. Although central mechanisms have been suggested to be the major cause of this low-frequency force potentiation, intramuscular factors might contribute. Thus, we hypothesized that two intramuscular Ca2+-dependent mechanisms can contribute to the low-frequen...
متن کاملThe effect of work cycle frequency on the potentiation of dynamic force in mouse fast twitch skeletal muscle.
The purpose of this study was to test the hypothesis that the potentiation of concentric twitch force during work cycles is dependent upon both the speed and direction of length change. Concentric and eccentric forces were elicited by stimulating muscles during the shortening and lengthening phases, respectively, of work cycles. Work cycle frequency was varied in order to vary the speed of musc...
متن کاملProlonged force increase following a high-frequency burst is not due to a sustained elevation of [Ca2+]i.
A brief high-frequency burst of action potentials results in a sustained force increase in skeletal muscle. The present study investigates whether this force potentiation is the result of a sustained increase of the free myoplasmic [Ca2+] ([Ca2+]i). Single fibers from mouse flexor brevis muscles were stimulated with three impulses at 150 Hz (triplet) at the start of a 350-ms tetanus or in the m...
متن کاملمعرفی روش استفاده از سیگنال مکانومیوگرام در ارزیابی عملکرد عضلات
Background and aims Recordings of electrical activity in the muscle and surface electromyography (EMG) have been widely used in the field of applied physiology. In parallel to recording of the EMG, the detectable low-frequency vibration signal generated by the skeletal muscle has been known and well documented. As the nature of the signal has been progressively revealed, the term of mec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 88 6 شماره
صفحات -
تاریخ انتشار 2000