Understanding Off-Label Use and Reference Blood Flows in Modern Membrane Oxygenators.
نویسنده
چکیده
This editorial will address two issues that are still a source of global controversy and confusion in present day perfusion practice. Membrane oxygenators are designed and tested to a set of stringent flow standards prior to their release from every manufacturer. But how well do we know the iatrogenic consequences of pushing these devices beyond their maximum rated limits? In addition, how well do we know the meaning of the term 'AAMI Reference Flow' as it relates to the Manufacturers Maximum Rated Flow?
منابع مشابه
An in vitro comparison of gas transfer and pressure drop of the Bentley Duraflo Coated Spiral Gold and the Medtronic Carmeda Coated Maxima hollow fiber membrane oxygenators.
Two models of heparin coated, hollow fiber membrane oxygenators were tested in vitro to compare gas transfer and transoxygenator pressure drop using an established protocol. Oxygen and carbon dioxide transfer rates were measured at blood flows of 2.5 and 5.0 liters per minute with gas flow: blood flow ratios of 1:1 and 2:1 at both blood flows. All testing was performed under normothermic condit...
متن کاملQuantification of Carbon Dioxide Removal at Low Sweep Gas and Blood Flows.
Advancement in oxygenator membrane technology has further expanded the boundaries in the clinical application of extracorporeal carbon dioxide removal (ECCO2R). Despite the advent of modern poly-4-methyl-1-pentene (PMP) membranes, limited information exists on the performance of these membranes at low sweep gas and blood flows. Moreover, physiological relationships for CO2 removal at these flow...
متن کاملنگرشی بر سیر تکاملی و کاربردهای بالینی اکسیژناتورها: گذشته، حال و آینده
Several therapeutic methods require an artificial lung (oxygenator) to replace the physiological function of lung. For instance, in some acute respiratory syndromes, the patient’s lungs are unable to perform their normal function and would need an assistive device to fulfill their performance. Moreover, in cardio-pulmonary bypass, when the heart has stopped pumping, blood is not sent to the lun...
متن کاملNon-destructive evaluation of membrane lung gas exchange performance.
This paper describes a method of evaluating the gas exchange effectiveness of hollow fiber oxygenators utilizing gas on both sides of the membrane. The goal of the study was to develop an evaluation technique which was accurate, reliable, and did not harm or contaminate a new, sterile oxygenator. Three pediatric oxygenators were tested and compared: the Medtronic Minimax Plus, the Terumo Capiox...
متن کاملThe Relationship Between Membrane Oxygenator Blood Path Pressure Drop and Hemolysis: An In-vitro Evaluation
Plasma hemoglobin (pl-Hgb) production was measured for the Bard HF-5000 (n = 4 ), Sams SMO (n =4) and Sams Turbo (n =4) membrane oxygenators (MO), which were tested on separate closed-loop roller pump circuits to compare differences in hemolysis production as a function of pressure drop (P). The three oxygenators were selected because of their varied P characteristics. Circuits were prepared by...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 46 3 شماره
صفحات -
تاریخ انتشار 2014