Inhibition of bipolar demand pacemaker by diaphragmatic myopotentials.

نویسندگان

  • S S Barold
  • L S Ong
  • M D Falkoff
  • R A Heinle
چکیده

This report describes inhibition of a normally functioning bipolar demand pulse generator by diaphragmatic myopotentials. Transient pacemaker suppression occurred repeatedly with deep respiration, straining, the Valsalva maneuver, coughing, sneezing and laughing. When the magnet was applied, none of these maneuvers inhibited the pacemaker. Extensive investigations ruled out an intermittent electrode problem such as a wire fracture or insulation break. Sensing of diaphragmatic myopotentials should be considered in the differential diagnosis of unexplained pacemaker pauses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CASE REPORTS Inhibition of Bipolar Demand Pacemaker by Diaphragmatic Myopotentials

INHIBITION OF DEMAND PACEMAKERS by musculoskeletal potentials has been reported to occur only with unipolar pacing systems.1 14 Mymin et al.,2 however, described one case of apparent suppression of a bipolar unit by myopotentials but gave no details about the mechanism of interference. Peter et al.", recently described transient inhibition of a unipolar demand pacemaker during deep respiration ...

متن کامل

Myopotential inhibition of a bipolar pacemaker caused by electrode insulation defect.

A patient is described in whom myopotentials orginating from the anterior abdominal wall muscle suppressed the implanted demand pacemaker despite its bipolar mode of action. This phenomenon was shown by simultaneous recording of the electrocardiogram the electromyogram. At operation, a defect in the insulation of a previously repaired epicardial electrode was found lying in close proximity to t...

متن کامل

Inhibition of external demand pacemakers during muscular activity.

Following the demonstration of external demand pacemaker inhibition by myopotentials from the pectoralis major muscle, a study was made of the frequency and cause of this phenomenon and its effect on different pacemaker units. Of the ii patients with complete atrioventricular block studied, 8 showed pacemaker inhibition during arm movement; in 3, with prolonged asystole, this was associated wit...

متن کامل

Inappropriate inhibition of biventricular pacing due to diaphragmatic myopotentials amplified by the selectable sensing filter.

A 66-year-old man with a cardiac resynchronization therapy defibrillator (CRT-D: Quadra Assura 3367-40QC, St. Jude Medical Inc.) experienced asymptomatic intermittent inhibition of biventricular pacing, mainly after meals. All measured parameters of the true bipolar ventricular lead (Durata 7122Q, St. Jude Medical Inc.) were in the normal range and general provocative maneuvers could not reprod...

متن کامل

Interference effect of myopotenitals on function of unipolar demand pacemakers.

Of 44 patients with demand pacemakers, 33 had pacemaker rhythm and were examined for failure in pacemaker function produced by myopotentials. Most patients were subjected to a standard experimental programme, with simultaneous recording of electrocardiogram and electromyogram. In 28 of the 33 patients the pacemaker was inhibited by muscle potentials. Three patients had suffered symptoms which c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 56 4 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1977