Noninvasive estimation of serum bilirubin.

نویسندگان

  • R Tayaba
  • D Gribetz
  • I Gribetz
  • I R Holzman
چکیده

OBJECTIVE The aim of this study was to evaluate the accuracy and clinical usefulness of a new computer-driven, hand-held device (Chromatics Colormate III) to estimate serum bilirubin from skin-reflectance (skin color) of neonates. STUDY DESIGN A total of 2441 infants (both term and premature) at two hospitals had repeated measurements of transcutaneous bilirubin. Of these infants, 900 had one or more laboratory determinations of serum bilirubin. Many of the infants had early measurements of skin color before the onset of jaundice. A visual estimate of the degree of jaundice was made by a health care worker when the laboratory study was drawn. A subgroup of 61 infants was also studied while undergoing phototherapy with a total of 284 comparisons obtained. The reproducibility of the instrument was assessed separately using standardized color tiles and repeated measurements by multiple operators. RESULTS The range of serum bilirubin measurements that had concurrent skin color measurements was 3.22 to 338.1 micromol/L (0.2 to 21 mg/dL). The linear regression indicated an r = 0.956, and 95% of the skin color measurements were within 32.2 micromol/L (2.0 mg/dL). There was no interference with the accuracy of the device because of infant race or weight, or because of the use of phototherapy. The device provided reproducible information when infants were tested repeatedly over 30 minutes; the coefficient of variation for the transcutaneous bilirubin measurement was 3.1% around a mean estimate of 135.32 micromol/L (8.4 mg/dL). CONCLUSION The Chromatics Colormate III allows for a clinically useful estimate of serum bilirubin in a wide variety of infants. By using a color discrimination algorithm and obtaining a skin measurement before the onset of icterus, this instrument can provide valuable clinical information that obviates the need for serum bilirubin determinations. Its use in newborn nurseries may allow physicians to shorten length of stay more safely and decrease the use of invasive blood tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates

Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...

متن کامل

Transcutaneous bilirubinometry: an evaluation.

The transcutaneous bilirubinometer was evaluated in 60 term and 10 preterm infants. A significant correlation was found between the transcutaneous index and the total serum bilirubin concentration for both term and preterm infants. The reliability of the transcutaneous bilirubinometer as a screening method was confirmed, and index criteria for serum bilirubin analysis have been suggested for te...

متن کامل

Noninvasive detection of bilirubin using pulsatile absorption.

Bilirubin, the yellow substance usually responsible for neonatal jaundice, is currently monitored invasively or by observing/measuring skin colour. This paper investigates the feasibility of monitoring serum bilirubin concentration using light absorbance in a similar fashion to pulse oximetry. The light absorbance of bilirubin is shown to be sufficiently different to haemoglobin to in theory al...

متن کامل

Neocherish - An Intelligent Care Unit For Neonatal Icterus

NeoCherish Noninvasive monitoring and treatment for neonatal icterus. Neonatal icterus, a problem in 60% of full term babies and 85% of pre-term babies. NeoCherish provides an effective solution for neonatal icterus. It is an intelligent system which is fully automatic noninvasive measurement of bilirubin in blood serum and treats with the higher wavelength LED (Light Emitting Diode) for cure. ...

متن کامل

Estimation of bilirubin binding capacity of neonatal serum.

One aim of laboratory investigation in neonatal jaundice is to prevent kernicterus from occurring. Estimation of the bilirubin-binding capacity of serum is an important measurement along with total bilirubin determination. With a convenient Sephadex competitive binding procedure, KERNLUTE provides information on whether or not the neonate's bilirubin-binding capacity has been exceeded. Further ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatrics

دوره 102 3  شماره 

صفحات  -

تاریخ انتشار 1998