A three dimensional analysis of slotted tube resonator for MRI

نویسندگان

  • Qiang Chen
  • Kunio Sawaya
  • Toru Uno
  • Saburo Adachi
  • Hisaaki Ochi
  • Etsuji Yamamoto
چکیده

A three dimensional model of a slotted tube resonator (STR) used as a probe in the magnetic resonance imaging (MRI), which is loaded by a dielectric body and surrounded by a conducting shield, is analyzed by using the variational method and the dyadic Green's function of a circular waveguide having a dielectric core. Three surface current modes are properly assumed to expand the currents on the STR. The characteristics such as the input impedance, the resonance frequency, the Q value, and the magnetic field distribution are obtained to show the effects of the dielectric body and the conducting shield. Some theoretical results are compared with the measured data to confirm the validity of the present analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Slotted end-ring volume coil for small animal Magnetic Resonance Imaging at 7T

Introduction. The development of transceiver volume coils for high field MRI is still a very dynamic field of investigation and development. A volume coil based on the high frequency cavity resonator [1] is presented in this paper for whole-body MRI of rodents at 7 Tesla (proton frequency: 299.47 MHz). This coil design has been previously tested on phantoms at 170 MHz (4T for protons) with stan...

متن کامل

Numerical Study on the Crushing Behavior of Square Tubes Under Three Dimensional Oblique Loading

This study aims to numerically investigate on the crashworthiness of thin-walled square tubes by consideration of 3-D oblique loading. In this type of loading, direction of loading is defined by using two spatial angles relative to the position of the tube. To this aim, finite element (FE) analysis is employed to simulate the loading for 8 different numerical models with different loading orien...

متن کامل

Analysis of Protein Concentration Based on Photonic Crystal Ring Resonator

In this paper, homogeneous, wavelength shift biosensor is designed for sensing the protein concentration using two dimensional Photonic Crystal Ring Resonator (PCRR). The sensor is designed to monitor the protein concentration from 0% to 100%. The proposed sensor is composed of periodic Si rods embedded in an air host with a circular PCRR that is placed between the inline quasi waveguides. It i...

متن کامل

Stacked-and-drawn metamaterials with magnetic resonances in the terahertz range.

We present a novel method for producing drawn metamaterials containing slotted metallic cylinder resonators, possessing strong magnetic resonances in the terahertz range. The resulting structures are either spooled to produce a 2-dimensional metamaterial monolayer, or stacked to produce three-dimensional multi-layered metamaterials. We experimentally investigate the effects of the resonator siz...

متن کامل

Dimensional Similarity in the Study of Microbubble Production Inside Venturi Tube

The present study considers of the water and air flow and Micro-Bubble production inside the venturi tube, by the use of dimensional analysis. Numerical analysis of Micro-Bubble creation in venturi tube requires fast computers and large amounts of storage space. Up to now, there has been no numerical analysis concerning Micro-Bubble creation and all other existing studies are experimental. To s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • IEEE transactions on medical imaging

دوره 13 4  شماره 

صفحات  -

تاریخ انتشار 1994