Low flow extracorporeal CO2 removal in ARDS patients: a prospective short-term crossover pilot study

نویسندگان

  • Harlinde Peperstraete
  • Sunny Eloot
  • Pieter Depuydt
  • Filip De Somer
  • Carl Roosens
  • Eric Hoste
چکیده

BACKGROUND Lung protective mechanical ventilation (MV) is the corner stone of therapy for ARDS. However, its use may be limited by respiratory acidosis. This study explored feasibility of, effectiveness and safety of low flow extracorporeal CO2 removal (ECCO2R). METHODS This was a prospective pilot study, using the Abylcap® (Bellco) ECCO2R, with crossover off-on-off design (2-h blocks) under stable MV settings, and follow up till end of ECCO2R. Primary endpoint for effectiveness was a 20% reduction of PaCO2 after the first 2-h. Adverse events (AE) were recorded prospectively. We included 10 ARDS patients on MV, with PaO2/FiO2 < 150 mmHg, tidal volume ≤ 8 mL/kg with positive end-expiratory pressure ≥ 5 cmH2O, FiO2 titrated to SaO2 88-95%, plateau pressure ≥ 28 cmH2O, and respiratory acidosis (pH <7.25). RESULTS After 2-h of ECCO2R, 6 patients had a ≥ 20% decrease in PaCO2 (60%); PaCO2 decreased 28.4% (from 58.4 to 48.7 mmHg, p = 0.005), and pH increased (1.59%, p = 0.005). ECCO2R was hemodynamically well tolerated. During the whole period of ECCO2R, 6 patients had an AE (60%); bleeding occurred in 5 patients (50%) and circuit thrombosis in 3 patients (30%), these were judged not to be life threatening. CONCLUSIONS In ARDS patients, low flow ECCO2R significantly reduced PaCO2 after 2 h, Follow up during the entire ECCO2R period revealed a high incidence of bleeding and circuit thrombosis. TRIAL REGISTRATION https://clinicaltrials.gov identifier: NCT01911533 , registered 23 July 2013.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative Low Flow Extra Corporeal Co2-Removal in Ards Patients: A Pilot Study

Introduction Mechanical ventilation (MV) of patients with Acute Respiratory Distress Syndrome (ARDS) should be performed with a lung protective strategy, since this is associated with better clinical outcomes. Lung protective MV contains the lowering of the plateau pressure (PPLAT) and the tidal volume (VT). Physician’s choice for lung protective MV can be hindered by the consequence of decreas...

متن کامل

A validation carried out on 10 pigs

The Extracorporeal CO2 removal device (ECCO2RD) is used in clinics to treat patients suffering from respiratory failures like acute respiratory distress syndrome (ARDS) or chronic obstructive pulmonary disease (COPD). The aim of this device is to decarboxylate blood externally with low blood flow. A mathematical model is proposed to describe protective ventilation, ARDS and an extracorporeal CO...

متن کامل

Randomized clinical trial of pressure-controlled inverse ratio ventilation and extracorporeal CO2 removal for adult respiratory distress syndrome.

The impact of a new therapy that includes pressure-controlled inverse ratio ventilation followed by extracorporeal CO2 removal on the survival of patients with severe ARDS was evaluated in a randomized controlled clinical trial. Computerized protocols generated around-the-clock instructions for management of arterial oxygenation to assure equivalent intensity of care for patients randomized to ...

متن کامل

Ultra-Low Tidal Volumes And Extracorporeal Carbon Dioxide Removal (Hemolung® Ras) in Ards Patients. a Clinical Feasibility Study

Introduction Ventilation of ARDS patients with low tidal volume (Vt) is performed in order to minimize ventilation induced lung injury. This strategy, however, may induce hypercapnic acidosis, promote derecruitment and, in some individuals, induce alveolar overdistention despite the use of low Vt. Extracorporeal CO2 removal can help minimizing hypercapnic acidosis and to further reduce Vt (i.e....

متن کامل

Low-flow CO2 removal integrated into a renal-replacement circuit can reduce acidosis and decrease vasopressor requirements

INTRODUCTION Lung-protective ventilation in patients with ARDS and multiorgan failure, including renal failure, is often paralleled with a combined respiratory and metabolic acidosis. We assessed the effectiveness of a hollow-fiber gas exchanger integrated into a conventional renal-replacement circuit on CO₂ removal, acidosis, and hemodynamics. METHODS In ten ventilated critically ill patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017