The Impact of Lens Opacity on SD-OCT Retinal Nerve Fiber Layer and Bruch's Membrane Opening Measurements Using the Anatomical Positioning System (APS).
نویسندگان
چکیده
Purpose To evaluate the impact of lens opacity on retinal nerve fiber layer thickness (RNFLT) and Bruch's membrane opening (BMO) measurements. Methods Fifty-nine randomly selected patients without any other relevant ocular pathology undergoing elective routine cataract surgery in two specialized eye clinics were enrolled. RNFLT, BMO area, and BMO minimum rim width (BMO-MRW) were assessed with the Heidelberg Engineering Spectralis OCT using the anatomical positioning system (APS) prior to and 1 day after cataract surgery using a ring scan at different eccentricities of the disc (3.5, 4.1 and 4.7 mm). Lens opacity was quantified using densitometry based on Scheimpflug images (Oculus Pentacam AXL). Results RNFLT, BMO area, and BMO-MRW were virtually identical before and following removal of the cataractous lens. This held when assessed overall, within the six sectors for the 3.5-mm scan, or at any other eccentricity. Baseline RNFLT was not associated with lens opacity. Conclusions Using the APS, RNFLT remained unchanged following cataract surgery, contrary to results reported by previous studies. Our results imply that the APS may have contributed to more precise spectral-domain optical coherence measurements, minimizing the influence of cataract on RNFLT and BMO assessments in our cohort.
منابع مشابه
Effect of Media Opacity on Retinal Nerve Fiber Layer Thickness Measurements by Optical Coherence Tomography
PURPOSE To assess the effect of ocular media opacity on retinal nerve fiber layer (RNFL) thickness measurements by optical coherence tomography (OCT). METHODS In this prospective, non-randomized clinical study, ocular examinations and OCT measurements were performed on 77 cataract patients, 80 laser refractive surgery patients and 90 patients whose signal strength on OCT was different on two ...
متن کاملBruch's Membrane Opening Minimum Rim Width Measurement with SD-OCT: A Method to Correct for the Opening Size of Bruch's Membrane
A precise evaluation of the retinal nerve fiber layer thickness (RNFLT) is key for diagnosing and monitoring glaucoma. The Bruch's membrane opening minimum rim width (BMO-MRW) has been proposed as a reproducible assessment of the optic nerve. The BMO-MRW measures the minimum distance from the BMO to the internal limiting membrane. We propose an approach to correct the BMO-MRW using the BMO size...
متن کاملIntraday Repeatability of Bruch's Membrane Opening-Based Neuroretinal Rim Measurements.
Purpose To assess possible intraday variability in Bruch's membrane opening-based (BMO) assessment of neuroretinal rim by spectral-domain optical coherence tomography (SD-OCT) of the optic nerve head (ONH) as well as to evaluate its independence from intraindividual IOP changes. Methods In this noninterventional, prospective cohort study, 51 consecutively enrolled patients with glaucoma or oc...
متن کاملOptic Nerve Head Development in Healthy Infants and Children Using Handheld Spectral-Domain Optical Coherence Tomography
PURPOSE To determine feasibility of optic nerve head (ONH) imaging and to characterize ONH development in full-term infants without sedation using handheld spectral-domain optical coherence tomography (SD OCT). DESIGN Prospective cross-sectional study. PARTICIPANTS Three hundred fifty-two children aged between 1 day and 13 years. METHODS All participants were imaged using handheld SD OCT ...
متن کاملCross-sectional anatomic configurations of peripapillary atrophy evaluated with spectral domain-optical coherence tomography.
PURPOSE To evaluate the cross-sectional configurations of peripapillary atrophy (PPA)-alpha and -beta in ophthalmologically normal subjects using spectral domain-optical coherence tomography (SD-OCT). METHODS One hundred twenty normal subjects had a complete ophthalmic examination including axial length measurement, standard automated perimetry, fundus imaging with photography, and SD-OCT (3D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 58 5 شماره
صفحات -
تاریخ انتشار 2017