Sinusoidal Microchannel with Descending Curves for Varicose Veins Implantation

نویسندگان

  • Muhammad Javaid Afzal
  • Muhammad Waseem Ashraf
  • Shahzadi Tayyaba
  • M. Khalid Hossain
  • Nitin Afzulpurkar
چکیده

Approximately 26% of adult people, mostly females, are affected by varicose veins in old age. It is a common reason for distress, loss of efficiency, and worsening living conditions. Several traditional treatment techniques (sclerotherapy and foam sclerotherapy of large veins, laser surgeries and radiofrequency ablation, vein ligation and stripping, ambulatory phlebectomy, and endoscopic vein surgery) have failed to handle this disease effectively. Herein, authors have presented an alternative varicose vein implant method—the descending sinusoidal microchannel (DSMC). DSMC was simulated by Fuzzy logic MATLAB (The MathWorks, Natick, MA, USA) and ANSYS (ANSYS 18.2, perpetual license purchased by Ibadat Education Trust, The University of Lahore, Pakistan) with real and actual conditions. After simulations of DSMC, fabrication and testing were performed. The silver DSMC was manufactured by utilizing a micromachining procedure. The length, width, and depth of the silver substrate were 51 mm, 25 mm, and 1.1 mm, respectively. The measurements of the DSMC channel in the silver wafer substrate were 0.9 mm in width and 0.9 mm in depth. The three descending curves of the DSMC were 7 mm, 6 mm, and 5 mm in height. For pressure, actual conditions were carefully taken as 1.0 kPa to 1.5 kPa for varicose veins. For velocity, actual conditions were carefully taken as 0.02 m/s to 0.07 m/s for these veins. These are real and standard values used in simulations and experiments. At Reynolds number 323, the flow rate and velocity were determined as 1001.0 (0.1 nL/s), 11.4 cm/s and 1015.3 (0.1 nL/s), 12.19 cm/s by MATLAB (The MathWorks, Natick, MA, USA) and ANSYS simulations, respectively. The flow rate and velocity were determined to be 995.3 (0.1 nL/s) and 12.2 cm/s, respectively, at the same Reynolds number (323) in the experiment. Moreover, the Dean number was also calculated to observe Dean vortices. All simulated and experimental results were in close agreement. Consequently, DSMC can be implanted in varicose veins as a new treatment to preserve excellent blood flow in human legs from the original place to avoid tissue damage and other problems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tissue remodeling investigation in varicose veins

Although the etiology of varicose veins remains unknown, recent studies have focused on endothelial cell integrity and function because the endothelium regulates vessel tone and synthesizes many pro- and anti-inflammatory factors. The aim of this study was to investigate the evidence involving the endothelium in the development of varicose vein disease. In addition, tissue remodeling was invest...

متن کامل

بررسی تأثیر مداخلات حرکتی بر کیفیت زندگی کاری آرایشگران زن مبتلا به بیماری وریدهای واریسی شهر همدان

Introduction: Varicose veins in the lower limbs commonly occur in the general population and can negatively affect their quality of life. One of the high-risk jobs is the field hairdressers. The aim of this study was to investigate the effects of ergonomic interventions on quality of life of female hairdressers suffering from diseases in the lower extremities varicose veins. Methods: The stu...

متن کامل

A proton induced X-ray emission (PIXE) analysis of concentration of trace elements in varicose veins

Background: Proton induced X-ray emission (PIXE) has been applied as reliable and improved techniques in this study to compare concentration of various trace elements in normal and abnormal varicose veins. Materials and Methods: Five samples from normal veins and 13 samples from varicose veins bombarded by 2.0 MeV energy proton beams produced by a Van de Graff accelerator in vacuum. T...

متن کامل

واریس وریدهای اندام تحتانی و ارتباط آن با برخی عوامل خطر در پرستاران شاغل در بیمارستانهای آموزشی دانشگاه علوم پزشکی بیرجند

Background and Aim: Kinds of job and body posture during work are among main risk factors for varicose veins. Among different jobs, nursing needs high mobility, long time standing and tiring physical positions that are necessary in performing nursing duty. This survey aimed at determining lower body organs varicose veins prevalence and its relationship with some risk factors among registered nu...

متن کامل

بررسی ارتباط پلی‌مورفیسم C677T ژن متیلن تتراهیدروفولات ردوکتاز (MTHFR) با وریدهای واریسی در جمعیت مازندران

Background: Methylenetetrahydrofolate reductase (MTHFR) is one of the key enzymes in the metabolism of folate, and the mutation of C677T leads to reduction of MTHFR enzyme activity and increases the risk of cardiovascular diseases. The aim of this study was to investigate the association between C677T polymorphism in MTHFR gene and some non-genetic factors and varicose veins. Methods: In this ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018