The Effect of Isometric Massage on Global Grip Strength after Conservative Treatment of Distal Radial Fractures. Pilot Study.
نویسندگان
چکیده
BACKGROUND The most common fracture of the distal end of the radius is Colles' fracture. Treatment modalities available for use in hand rehabilitation after injury include massage. The aim of this study was to evaluate the effect of isometric massage on the recovery of hand function in patients with Colles fractures. For this purpose, the strength of the finger flexors was assessed as an objective criterion for the evaluation of hand function. MATERIAL AND METHODS The study involved 40 patients, randomly divided into Group A of 20 patients and Group B of 20 patients. All patients received physical therapy and exercised individually with a physiotherapist. Isometric massage was additionally used in Group A. Global grip strength was assessed using a pneumatic force meter on the first and last day of therapy. Statistical analysis was performed using STATISTICA. Statistical significance was defined as a P value of less than 0.05. RESULTS In both groups, global grip strength increased significantly after the therapy. There was no statistically significant difference between the groups. The men and women in both groups equally improved grip strength. A statistically significant difference was demonstrated between younger and older patients, with younger patients achieving greater gains in global grip strength in both groups. CONCLUSION The incorporation of isometric massage in the rehabilitation plan of patients after a distal radial fracture did not significantly contribute to faster recovery of hand function or improve their quality of life.
منابع مشابه
Short-term Results of Using Injectable Bone Cement Technique in the Treatment of Unstable Distal Radius Fractures
Background & Aims: Treatment of osteoporotic distal radius fracture with metaphyseal defect is often complicated by secondary displacement, because of posterior cortex comminution. The aim of this study was to investigate functional outcomes and advantages of injection of bone cement in stabilizing and maintaining this fracture reduction. Methods: This prospective study was performed on 20 ...
متن کاملFunctional Outcome of Internal Fixation of Radial and Ulna Fracture
Background: Displaced fractures of radius and ulna bones in adults are usually treated with open reduction and internal fixation. The purpose of this research was to access functional outcome of these fractures. Materials and Methods: In this research 52 Patients who underwent ORIF with DCP 3.5 in past 5 years were investigated. Post-operation protocol was one week immobilization and then acti...
متن کاملThe Best Option in Treatment of Modified Mason Type III Radial Head Fractures: Open Reduction and Internal Fixation Versus Radial Head Excision
Background: Radial head fractures commonly occur during elbow traumas. Among those, treatment of Mason type IIIfractures is still under controversy. Common treatment methods for these fractures include open reduction and internalfixation (ORIF) as well as radial head excision. In this study, we compared long-term outcomes of both methods intreatment of patients with Mason type III fractures of ...
متن کاملExternal or internal fixation in the treatment of non-reducible distal radial fractures?
BACKGROUND AND PURPOSE We have previously shown in a randomized study that in the first year after treatment, open reduction and internal fixation resulted in better grip strength and forearm rotation than closed reduction and bridging external fixation. In the present study, we investigated whether this difference persists over time. PATIENTS AND METHODS The 50 patients included in the origi...
متن کاملDistal Radius Fracture Fixation With the Specialized Threaded Pin Device.
This study investigated the outcomes of extra-articular distal radius fractures and simple intra-articular radial styloid fractures stabilized with a novel threaded cannulated device. This was a retrospective study of 24 distal radius fractures treated with the T-Pin device (Union Surgical LLC, Philadelphia, Pennsylvania), with a minimum of 1 year of postoperative follow-up. Outcome data includ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ortopedia, traumatologia, rehabilitacja
دوره 17 4 شماره
صفحات -
تاریخ انتشار 2015