Operation and output pulse characteristics of an extremely compact capillary-discharge tabletop soft-x-ray laser.

نویسندگان

  • B R Benware
  • C H Moreno
  • D J Burd
  • J J Rocca
چکیده

We report on the operating parameters and laser output pulse characteristics of an extremely compact discharge-pumped 46.9-nm laser of a size comparable with that of many widely utilized visible and ultraviolet gas lasers. This capillary-discharge laser generated subnanosecond laser pulses with energies of as much as 25microJ by single-pass amplification in an 18.6-cm-long argon-plasma column. Measurements of the laser output energy, pulse width, far-field beam profile, and beam divergence are reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Demonstration of a High Average Power Tabletop Soft X-Ray Laser

We report the first demonstration of a high average power tabletop soft x-ray laser. An average laser output power of ø1 mW s.2 3 1014 photonsysd was generated at 46.9 nm in Ne-like Ar using a very compact tabletop discharge. The spatially coherent average power emitted by this 26.5 eV laser is comparable to that generated at this photon energy in a similar bandwidth sDlyl ­ 1024d by a thirdgen...

متن کامل

Extremely compact soft X-ray lasers based on capillary discharges

Extremely compact high repetition rate soft X-ray lasers based on capillary discharge excitation have demonstrated average powers of a few milliWatt at 46.9 nm, milli-Joule-level pulse energy, peak spectral brightness several orders of magnitude larger than third-generation synchrotron beam lines, and excellent spatial coherence. Examples of the use of a capillary discharge soft X-ray laser in ...

متن کامل

Soft-x-ray laser interferometry of a plasma with a tabletop laser and a Lloyd's mirror.

We report what is believed to be the first demonstration of soft-x-ray interferometry of a plasma with a tabletop soft-x-ray laser. A Lloyd's mirror interferometer was used in combination with a very compact lambda = 46.9 nm capillary-discharge-pumped laser to map the electron density in the cathode region of a pinch plasma.

متن کامل

Generation of millijoule-level soft-x-ray laser pulses at a 4-Hz repetition rate in a highly saturated tabletop capillary discharge amplifier.

Laser pulses with energies of as much as 1 mJ were generated at a wavelength of 46.9 nm by single-pass amplification in a 34.5 cm-long Ne-like Ar capillary discharge plasma. The large gain-length product of this plasma column allows for soft-x-ray amplification in a highly saturated regime, resulting in efficient energy extraction. Average laser output pulse energy of 0.88 mJ and peak power of ...

متن کامل

Application of extremely compact capillary discharge soft x-ray lasers to dense plasma diagnostics

Table-top capillary discharge soft x-ray lasers combine the advantages of a small size and a high repetition rate with an extremely high brightness similar to that of their laboratory-size predecessors. When utilized to probe high density plasmas their short wavelength results in a higher critical density, reduced refraction, decreased free-electron absorption, and higher resolution as compared...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 22 11  شماره 

صفحات  -

تاریخ انتشار 1997