Operation and output pulse characteristics of an extremely compact capillary-discharge tabletop soft-x-ray laser.
نویسندگان
چکیده
We report on the operating parameters and laser output pulse characteristics of an extremely compact discharge-pumped 46.9-nm laser of a size comparable with that of many widely utilized visible and ultraviolet gas lasers. This capillary-discharge laser generated subnanosecond laser pulses with energies of as much as 25microJ by single-pass amplification in an 18.6-cm-long argon-plasma column. Measurements of the laser output energy, pulse width, far-field beam profile, and beam divergence are reported.
منابع مشابه
Demonstration of a High Average Power Tabletop Soft X-Ray Laser
We report the first demonstration of a high average power tabletop soft x-ray laser. An average laser output power of ø1 mW s.2 3 1014 photonsysd was generated at 46.9 nm in Ne-like Ar using a very compact tabletop discharge. The spatially coherent average power emitted by this 26.5 eV laser is comparable to that generated at this photon energy in a similar bandwidth sDlyl 1024d by a thirdgen...
متن کاملExtremely compact soft X-ray lasers based on capillary discharges
Extremely compact high repetition rate soft X-ray lasers based on capillary discharge excitation have demonstrated average powers of a few milliWatt at 46.9 nm, milli-Joule-level pulse energy, peak spectral brightness several orders of magnitude larger than third-generation synchrotron beam lines, and excellent spatial coherence. Examples of the use of a capillary discharge soft X-ray laser in ...
متن کاملSoft-x-ray laser interferometry of a plasma with a tabletop laser and a Lloyd's mirror.
We report what is believed to be the first demonstration of soft-x-ray interferometry of a plasma with a tabletop soft-x-ray laser. A Lloyd's mirror interferometer was used in combination with a very compact lambda = 46.9 nm capillary-discharge-pumped laser to map the electron density in the cathode region of a pinch plasma.
متن کاملGeneration of millijoule-level soft-x-ray laser pulses at a 4-Hz repetition rate in a highly saturated tabletop capillary discharge amplifier.
Laser pulses with energies of as much as 1 mJ were generated at a wavelength of 46.9 nm by single-pass amplification in a 34.5 cm-long Ne-like Ar capillary discharge plasma. The large gain-length product of this plasma column allows for soft-x-ray amplification in a highly saturated regime, resulting in efficient energy extraction. Average laser output pulse energy of 0.88 mJ and peak power of ...
متن کاملApplication of extremely compact capillary discharge soft x-ray lasers to dense plasma diagnostics
Table-top capillary discharge soft x-ray lasers combine the advantages of a small size and a high repetition rate with an extremely high brightness similar to that of their laboratory-size predecessors. When utilized to probe high density plasmas their short wavelength results in a higher critical density, reduced refraction, decreased free-electron absorption, and higher resolution as compared...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 22 11 شماره
صفحات -
تاریخ انتشار 1997