Assessment of the gain transfer function of phosphors for application in medical imaging radiation detectors.

نویسندگان

  • D Cavouras
  • I Kandarakis
  • T Maris
  • G S Panayiotakis
  • C D Nomicos
چکیده

OBJECTIVE to study various phosphors used in detectors of medical imaging systems by the gain transfer function (GTF), defined in terms of X-ray luminescence efficiency, light spectrum and modulation transfer function. MATERIALS AND METHODS four phosphor materials, La(2)O(2)S:Tb, Y(2)O(2)S:Tb, Y(2)O(2)S:Eu and Y(2)O(3):Eu were used in the form of fluorescent layers prepared in the laboratory. The GTF was determined at 30 kVp and 80 kVp X-ray tube voltages for various phosphor coating weights. RESULTS La(2)O(2)S:Tb, which was the highest density and effective atomic number phosphor used, was found to exhibit the best GTF performance at 80 kVp. At 30 kVp, the yttrium based phosphors were found of increased performance. This is mainly due to the proximity of the X-ray energy to the K-absorption edge of yttrium at 17 keV. Europium activated phosphors were found to perform very well when combined with the red sensitive film and the silicon photodiode. CONCLUSION The GTF may be a useful method for comparing and selecting phosphor materials for use in various medical imaging applications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of organ dose in abdomen-pelvis CT exam as a function of mA, KV and scanner type by Monte Carlo method .

Background: CT is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures, so the calculation of organ dose in CT exams is very important. While methods to calculate the effective dose have been established (ICRP 26 and ICRP 60), they depend heavily on the ability to estimate the dose to radiosensitive organs from the CT procedure. However, dete...

متن کامل

Verification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors

Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong  relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In  many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general,  the uncertainty in the dose delivered should fall within  ± 5% of the...

متن کامل

Comparison of ScintSim1 and Geant4 Monte Carlo simulation codes for optical photon transport in thick segmented scintillator arrays

  Introduction: Arrays of segmented scintillation crystals are useful in megavoltage x-ray imaging detectors for image-guided radiotherapy. Most previous theoretical studies on these detectors have modelled only ionizing-radiation transport. Scintillation light also affects detector performance. ScintSim1, our previously reported optical Monte Carlo code for such detector...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of radiology

دوره 35 1  شماره 

صفحات  -

تاریخ انتشار 2000