Expiratory peak flow and respiratory system resistance in mechanically ventilated patients undergoing two different forms of manually assisted cough.
نویسندگان
چکیده
OBJECTIVE Mechanical ventilation is associated with retained airway secretions. Manually assisted cough contributes to the displacement of bronchial mucus, whereas positive end-expiratory pressure increases collateral ventilation and maintains airway patency. This study aimed to assess the effects of manually assisted cough, either alone or added to increased positive end-expiratory pressure and inspiratory time (optimized manually assisted cough), on the expiratory peak flow and respiratory system mechanics in mechanically ventilated patients. METHODS In this controlled and randomized clinical trial, respiratory mechanics and expiratory peak flow were assessed in male and female patients undergoing either tracheal suctioning alone, manually assisted cough followed by tracheal suctioning or optimized manually assisted cough followed by tracheal suctioning. RESULTS Thirty-five patients completed the trial. Respiratory system resistance was significantly reduced after optimized manually assisted cough (16.0 ± 3.6 versus 12.4 ± 3.1 cmH2O/L/s; p = 0.04). The expiratory peak flow during optimized manually assisted cough was significantly higher in comparison with the values observed during manually assisted cough (112.3 ± 15.6 versus 95.8 ± 18.3 Lpm; p < 0.05). Both values were significantly higher than the values observed in the group undergoing tracheal suctioning alone (52.0 ± 7.6 Lpm; p < 0.001). CONCLUSION Optimized manually assisted cough increases the expiratory peak flow in comparison with manually assisted cough; in addition, this procedure reduces respiratory system resistance.
منابع مشابه
Expiratory rib cage compressions to improve secretion clearance during mechanical ventilation: not only a matter of squeezing the chest.
In Reply: We thank Dr Martí and his colleagues for their comments on our study. The different methods used to investigate the clinical and physiological repercussions of airway clearance techniques make comparison between studies difficult. Animal studies like those from Unoki et al1,2 and Martí et al3 are important to elucidate mechanisms and raise insights into safety and efficacy of clinical...
متن کاملEVect of manually assisted cough and mechanical insuZation on cough flow of normal subjects, patients with chronic obstructive pulmonary disease (COPD), and patients with respiratory muscle weakness
Background—It has been suggested that cough eVectiveness can be improved by assisted techniques. The eVects of manually assisted cough and mechanical insufflation on cough flow physiology are reported in this study. Methods—The physiological actions and patient self-assessment of manually assisted cough and mechanical insuZation were investigated in 29 subjects (nine normal subjects, eight pati...
متن کاملBench Comparative Assessment of Mechanically Assisted Cough Devices.
BACKGROUND Mechanically assisted cough devices are used in patients with impaired cough to avoid secretion accumulation. We compared 5 mechanically assisted cough devices by bench testing using a breathing simulator and assessed their user-friendliness. METHODS We measured inspiratory and expiratory airway pressures and peak expiratory flow, the strongest indicator of cough efficacy. We perfo...
متن کاملEvaluation of the Effect of Nebulized N-Acetylcysteine on Respiratory Secretions in Mechanically Ventilated Patients: Randomized Clinical Trial
Background: The purpose of our study was to evaluate an inexpensive and available method to reduce mucous impactions in mechanically ventilated patients.Methods: This randomized clinical trial was conducted on 40 mechanically ventilated patients aged 15-90 years. The patients were randomly allocated into two arms; 20 cases and 20 controls. The cases received N-acetylcysteine via their nebulizer...
متن کاملCan the Flutter Valve improve respiratory mechanics and sputum production in mechanically ventilated patients? A randomized crossover trial.
OBJECTIVE The Flutter Valve (Varioraw SARL, Scandipharm Inc, Birmingham, AL) has proven efficacy in hypersecretive spontaneously ventilated patients. This study was designed to evaluate whether an airway clearance protocol using the Flutter Valve can affect the therapeutic and physiologic outcomes in mechanically ventilated patients with pulmonary infection. METHODS In a randomized crossover ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista Brasileira de terapia intensiva
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2012