Performance Analyses of Counter-Flow Closed Wet Cooling Towers Based on a Simplified Calculation Method
نویسندگان
چکیده
As one of the most widely used units in water cooling systems, the closed wet cooling towers (CWCTs) have two typical counter-flow constructions, in which the spray water flows from the top to the bottom, and the moist air and cooling water flow in the opposite direction vertically (parallel) or horizontally (cross), respectively. This study aims to present a simplified calculation method for conveniently and accurately analyzing the thermal performance of the two types of counter-flow CWCTs, viz. the parallel counter-flow CWCT (PCFCWCT) and the cross counter-flow CWCT (CCFCWCT). A simplified cooling capacity model that just includes two characteristic parameters is developed. The Levenberg–Marquardt method is employed to determine the model parameters by curve fitting of experimental data. Based on the proposed model, the predicted outlet temperatures of the process water are compared with the measurements of a PCFCWCT and a CCFCWCT, respectively, reported in the literature. The results indicate that the predicted values agree well with the experimental data in previous studies. The maximum absolute errors in predicting the process water outlet temperatures are 0.20 and 0.24 ◦C for the PCFCWCT and CCFCWCT, respectively. These results indicate that the simplified method is reliable for performance prediction of counter-flow CWCTs. Although the flow patterns of the two towers are different, the variation trends of thermal performance are similar to each other under various operating conditions. The inlet air wet-bulb temperature, inlet cooling water temperature, air flow rate, and cooling water flow rate are crucial for determining the cooling capacity of a counter-flow CWCT, while the cooling tower effectiveness is mainly determined by the flow rates of air and cooling water. Compared with the CCFCWCT, the PCFCWCT is much more applicable in a large-scale cooling water system, and the superiority would be amplified when the scale of water distribution system increases. Without multiple iterative calculations and extensive experimental data, the simplified method could be used to effectively analyze the thermal performance of counter-flow CWCTs in operation. It is useful for optimization operation of counter-flow CWCTs such that to improve the energy efficiency of the overall cooling water system.
منابع مشابه
Dynamic Modeling of Mechanical Draft Counter-Flow Wet Cooling Tower with Modelica
Cooling towers are important equipments for the HVAC systems in commercial buildings, rejecting the process heat generation to the atmosphere. Dynamic modeling of cooling towers is beneficial for control design and fault detection and diagnostics of the chilled-water systems. This paper proposes a simple and yet effective dynamic model for a typical mechanical draft counter-flow wet cooling tow...
متن کاملPerformance Evaluation of Counter·flowwet Cooling Towers Using Exergetic Analysis
In this paper, performance evaluation of wet cooling tower is done. To achieve this aim, first, thermal behavior of counter-flow wet cooling tower is studied through a simulation model. The influence of the environmental conditions on the thermal efficiency of the cooling tower is investigated. The cooling tower performance is simulated in terms of varying air and water temperatures, and of the...
متن کاملA Comprehensive Approach to an Optimum Design and Simulation Model of a Mechanical Draft Wet Cooling Tower
The present paper describes the designing of a thermally and economically optimum mechanical draft counter-flow wet cooling tower. The design model allows the use of a variety of packing materials in the cooling tower toward optimizing heat transfer. Once the optimum packing type is chosen, a compact cooling tower with low fan power consumption is modelled within the known design variables....
متن کاملTwo Phase Flow Simulation for Subcooled Nucleat Boiling Heat Transfer Calculation in Water Jacket of Diesel Engine
Basic understanding of the process of coolant heat transfer inside an engine is an indispensable prerequisite to devise an infallible cooling strategy. Coolant flow and its heat transfer affect the cooling efficiency, thermal load of heated components, and thermal efficiency of a diesel engine. An efficient approach to studying cooling system for diesel engine is a 3D computational fluid dynami...
متن کاملEffect of Ambient Condition on the Shower Cooling Tower in Four Type of Climates Condition
Water cooling by ambient takes place with two mechanisms of heat and mass transfer. Using packings at wet cooling towers has disadvantages such as obstruction, reduction of life expectancy and production of algae and fungi. In shower cooling towers types of towers packings are completely removed and water intake is in direct contact and heat transfer takes place in two ways of latent and sensib...
متن کامل