AUTORADIOGRAPHY WITH THE ELECTRON MICROSCOPE A Procedure for Improving Resolution, Sensitivity, and Contrast
نویسنده
چکیده
Autoradiographic techniques for use with the electron microscope have been developed and considerably improved in recent years. A review of this historical development is given by Meek and Moses (14), and a theoretical analysis of the problems involved by Pelc (17) and Caro (4). In this paper, we describe a method for preparing autoradiographic specimens, using a new, fine-grained emulsion and a special, high-sensitivity developing technique. This procedure gives higher resolution, sensitivity, and specimen contrast than previously available. Fine-grained emulsion: The size of the undeveloped silver halide crystal and the thickness of the emulsion are among the limiting factors in autoradiographic resolution. Ideally, one wants a fine-grained emulsion coated in a closely packed monolayer. The Ilford L4 nuclear track emulsion with a silver halide grain size of 1200 to 1600 A is most frequently used for electron microscopic autoradiography. The Gevaert (Scientia Nuc. 307) emulsion has finer grains (700 A), but is reported to be difficult to handle (7). We obtained an experimental emulsion from Eastman Kodak ~ with an undeveloped grain size of 300 to 500 A. (Fig. 4 compares the grain size of this emulsion with that
منابع مشابه
Autoradiography with the Electron Microscope
Autoradiographic techniques for use with the electron microscope have been developed and considerably improved in recent years. A review of this historical development is given by Meek and Moses (14), and a theoretical analysis of the problems involved by Pelc (17) and Caro (4). In this paper, we describe a method for preparing autoradiographic specimens, using a new, fine-grained emulsion and ...
متن کاملOptimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system
Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...
متن کاملFreeze-fracture autoradiography: feasibility
We have shown that the combination of freeze-fracture with electron microscope autoradiography can be developed into a technique for correlating the molecular structure of the biological membrane with its chemical and functional characteristics. Within the limits of electron microscope autoradiographic resolution, FARG has the potential to detect the relative distribution of molecules in each h...
متن کاملResolution in electron microscope autoradiography. III. Iodine-125, the effect of heavy metal staining, and a reassessment of critical parameters
Resolution for 125I-labeled specimens under electron microscope (EM) autoradiographic conditions was assessed experimentally. With this isotope the size of the silver halide crystal was the most important resolution-limiting factor. Heavy metal staining such as is routinely used in preparing animal tissues for EM autoradiography produced an improvement in resolution of approximately 15-20%. For...
متن کاملElectron microscope autoradiography with special reference to the problem of resolution.
in the light of present knowledge, her challenge to electron microscope autoradiography has established an eternal monument as it has provoked present day progress in this field of science. Following her and other technical pioneers such as O'BRIEN and GEORGE (1959) and HARFORD and HAMLIN (1961), many technical difficulties were overcome by CARO (1961 a, b, 1964), SALPETER (1967) and other inve...
متن کامل