Determination of the Efficiency of Commercially Available Dose Calibrators for -Emitters

نویسندگان

  • Jean-François Valley
  • Claude Wastiel
چکیده

Objectives: The goals of this investigation are to determine whether commercially available dose calibrators can be used to measure the activity of -emitting radionuclides used in pain palliation and to establish whether manufacturer-supplied calibration factors are appropriate for this purpose. Methods: Six types of commercially available dose calibrators were studied. Dose calibrator response was controlled for 5 -emitters used for calibration or typically encountered in routine use. For the 4 most commonly used -emitters (32P, 90Sr, 90Y, and 169Er) dose calibrator efficiency was determined in the syringe geometry used for clinical applications. Efficiency of the calibrators was also measured for 153Sm and 186Re, 2 -emitters with significant -contributions. Source activities were traceable to national standards. Results: All calibrators measured -emitters with a precision of 10%, in compliance with Swiss regulatory requirements. For -emitters, dose calibrator intrinsic efficiency depends strongly on the maximal energy of the -spectrum and is notably low for 169Er. Manufacturer-supplied calibration factors give accurate results for -emitters with maximal -energy in the middle-energy range (1 MeV) but are not appropriate for use with low-energy (169Er) or high-energy (90Y) -emitters. -emitters with significant -contributions behave like -emitters. Conclusion: Commercially available dose calibrators have an intrinsic efficiency that is sufficient for the measurement of -emitters, including -emitters with a low maximum -energy. Manufacturer-supplied calibration factors are reliable for -emitters and -emitters in the middle-energy range. For lowand high-energy -emitters, the use of manufacturer-supplied calibration factors introduces significant measurement inaccuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation on the performance of dose calibrators in nuclear medicine centers in Iran

Background: To investigate the status of the nuclear medicine (NM) centers in Iran for the performance of dose calibrators, 18 out of 54 centers providing NM services in Iran were randomly selected and inspected in 1997. In the first phase of the study the selected centers were inspected for performing of quality control (QC) tests of dose calibrators. The linearity of the activity res...

متن کامل

Photostability Determination of Commercially Available Nifedipine Oral Dosage Forms in Iran

Nifedipine (NIF) a 1, 4-dihydropyridine calcium channel antagonist, undergoes photodegradation to nitroso analogues of dehydronifedipine (NDNIF) when exposed to sunlight. Photodegradation products of NIF have no clinical activity, so different formulations of NIF must remain unchanged. If NIF preparations become unstable in exposure to light, they could cause therapeutic failure. The present st...

متن کامل

Photostability Determination of Commercially Available Nifedipine Oral Dosage Forms in Iran

Nifedipine (NIF) a 1, 4-dihydropyridine calcium channel antagonist, undergoes photodegradation to nitroso analogues of dehydronifedipine (NDNIF) when exposed to sunlight. Photodegradation products of NIF have no clinical activity, so different formulations of NIF must remain unchanged. If NIF preparations become unstable in exposure to light, they could cause therapeutic failure. The present st...

متن کامل

Dosimetric measurements in isolated human coronary arteries: comparison of commercially available iridium(192) with strontium/yttrium(90) emitters.

BACKGROUND Intravascular brachytherapy is being applied more and more in patients with coronary artery disease for the prevention of restenosis subsequent to balloon angioplasty, in particular after stent implantation. Several radiation sources (beta- and gamma-emitters) are available in clinical routine. It was the purpose of this study to compare the radiation doses at the level of the advent...

متن کامل

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003