Reloading of the variceal multiple-band ligator using haemorrhoidal banding apparatus.
نویسنده
چکیده
Madam, Variceal ligation is the endoscopic procedure of choice to prevent recurrent variceal haemorrhage and eradicate varices 1,2 . Usually it takes 3-4 sessions for the purpose. Multiple band ligators are now available for rapid ligation 3,4 . These ligators do not require overtube or reloading of bands during the procedure and many bands may be deployed by just rotation of the pulley or handle attached to the endoscope’s accessory channel. These devices are intended for single use only and are too expensive and out of reach of cirrhotic patients coming from low socioeconomic classes. We have been reusing the multiple band ligator after reloading the barrel. We use the banding apparatus of haemorrhoids and haemorrhoidal bands for this process. Procedure: Disinfect the apparatus in glutaraldehyde solution. The plaited string or trigger cord of the multiple band ligator becomes separated into two threads near the barrel. Each thread has six beads at regular intervals starting from the tip of the thread. Pass these threads through the barrel of the multiple bands ligator from its scope-end side and deliver them from the transparent rim side. Now load the banding apparatus of haemorrhoids. Fit the metal cone at the end of the cylinder of the haemorrhoidal banding apparatus and roll the rubber band (ring) from the cone to the cylinder (Figure 1).
منابع مشابه
Esophageal Variceal Banding
Banding of esophageal varices was done in 29 patients suffering from acute variceal bleeding. In 13 patients this was the first bleed while in 16 it was recurrent. Five patients had large grade III (polypold) varices while others had grade II varices. Banding was done using multi band ligator and 4-6 bands were fired per session. Repeat endoscopy at 3 weeks revealed persistance of varices requi...
متن کاملSingle-thread multishooter ligator system shooting at the 7 o'clock position: an ideal band ligator.
doscopic variceal ligation. The Stieg− mann±Goff ligator works by pulling a string to deploy the band [1], but requires an overtube for multiple ligations. Saeed’s multishooter has the advantage of single insertion, pulling a single band at a time and is able to shoot six bands [2]. Most multishooters use a double thread, however, which hampers the en− doscopic view. Our single−thread system ha...
متن کاملLeak after Whipple Resection: Preventable?
133 While the safety of endoscopic banding liga-tion is largely undisputed, there is one major risk of this technique: esophageal perforation during insertion of the overtube. Perforation of the esophagus often occurs as a result of inability to relax the pharyngeal muscle by the patient and forceful insertion of the tube by the endoscopist. The development of multiple banding ligators (Speedba...
متن کاملA new method for endoscopic variceal band ligation in Zenker's diverticulum.
A 62-year-old man was admitted with hematemesis. He had been diagnosed to have hepatitis B-related cirrhosis 4 months earlier, and had not undergone esophagogastroduodenoscopy (EGD) previously. He had no history of dysphagia. During intubation with an endoscope (GIF Q-150, Olympus, Japan), resistance was encountered at the upper esophageal sphincter, and a diverticulum was noted at this level. ...
متن کامل3, 6 or 9-band shooters: tailor made ligators as needed.
Patients with portal hypertension require esophageal variceal ligation for primary or secondary prophylaxis of variceal bleed. These patients have grade II to IV varices, the number of columns are variable from 1 to 4. The length of the columns may be short, or may extend into the upper part of esophagus. The number of bands required varies according to the grade, number and length of esophagea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JPMA. The Journal of the Pakistan Medical Association
دوره 50 8 شماره
صفحات -
تاریخ انتشار 2000