Validity and repeatability of three in-shoe pressure measurement systems.

نویسندگان

  • Carina Price
  • Daniel Parker
  • Christopher Nester
چکیده

In-shoe pressure measurement devices are used in research and clinic to quantify plantar foot pressures. Various devices are available, differing in size, sensor number and type; therefore accuracy and repeatability. Three devices (Medilogic, Tekscan and Pedar) were examined in a 2 day×3 trial design, quantifying insole response to regional and whole insole loading. The whole insole protocol applied an even pressure (50-600kPa) to the insole surface for 0-30s in the Novel TruBlue™ device. The regional protocol utilised cylinders with contact surfaces of 3.14 and 15.9cm(2) to apply pressures of 50 and 200kPa. The validity (% difference and Root Mean Square Error: RMSE) and repeatability (Intra-Class Correlation Coefficient: ICC) of the applied pressures (whole insole) and contact area (regional) were outcome variables. Validity of the Pedar system was highest (RMSE 2.6kPa; difference 3.9%), with the Medilogic (RMSE 27.0kPa; difference 13.4%) and Tekscan (RMSE 27.0kPa; difference 5.9%) systems displaying reduced validity. The average and peak pressures demonstrated high between-day repeatability for all three systems and each insole size (ICC≥0.859). The regional contact area % difference ranged from -97 to +249%, but the ICC demonstrated medium to high between-day repeatability (ICC≥0.797). Due to the varying responses of the systems, the choice of an appropriate pressure measurement device must be based on the loading characteristics and the outcome variables sought. Medilogic and Tekscan were most effective between 200 and 300kPa; Pedar performed well across all pressures. Contact area was less precise, but relatively repeatable for all systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity and repeatability of three commercially available in-shoe pressure measurement systems

Background In-shoe pressure measurement devices are commonly used in research and clinical settings to quantify pressure on the plantar foot. Various in-shoe pressure measurement devices are currently available and they differ in their size, number of sensors, sensor type and therefore their loading response and accuracy. Previous comparisons focus on pressure plates [1]. An in-shoe study highl...

متن کامل

The Pedar in-shoe system: repeatability and normal pressure values.

The Pedar system is one of the most commonly used systems for in-shoe pressure measurement. Good repeatability is necessary to ensure the consistency of measurements on which clinical judgements are based. In addition, there is a need to establish a range of normal in-shoe pressure values, which will help to identify abnormalities. The aim of this study was to assess the repeatability of the Pe...

متن کامل

تاثیر کفی فانکشنال و کفش طبی بر تعادل ایستایی در کودکان دچار صافی کف پا انعطاف پذیر

Objective: Flat foot is common deformity in children that medial longitudinal arch is decreased, which if not treated in childhood may lead to pain and other problems in adulthood. Insoles and orthopedic shoes usually prescribed for treatment of flat foot in children, but the biomechanical impact of these devices is not yet clear. The purpose of this study is comparison of two conventional orth...

متن کامل

A Dynamic Coefficient of Friction Measurement Device for Shoe/Floor Interface Testing

A dynamic coefficient of friction (COF) measurement device is described for use in recording shoe/floor slip resistance. This device is computercontrolled and allows changes in the shoe/floor interface velocity and vertical force applied during a test. Different sole materials, floors, and contaminants such as water or oil are testable. Repeatability tests of the device were conducted of four v...

متن کامل

Repeatability of the Pedar-X in-shoe pressure measuring system.

BACKGROUND The Pedar-X is one of the newer versions of in-shoe pressure measuring devices and the current study aimed to assess the repeatability of this device. METHODS Twenty-seven healthy male volunteers were recruited and requested to walk on a 26-feet walkway wearing appropriate sized standardised off-the-shelf neutral running shoes (Donnay International). The Pedar-X insole was sandwich...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gait & posture

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2016