Nuclear reactor pulse tracing using a CdZnTe electro-optic radiation detector

نویسندگان

  • Kyle A. Nelson
  • Jeffrey A. Geuther
  • James L. Neihart
  • Todd A. Riedel
  • Ronald A. Rojeski
  • Philip B. Ugorowski
  • Douglas S. McGregor
چکیده

CdZnTe has previously been shown to operate as an electro-optic radiation detector by utilizing the Pockels effect to measure steady-state nuclear reactor power levels. In the present work, the detector response to reactor power excursion experiments was investigated. Peak power levels during an excursion were predicted to be between 965 MW and 1009 MW using the Fuchs–Nordheim and Fuchs– Hansen models and confirmed with experimental data from the Kansas State University TRIGA Mark II nuclear reactor. The experimental arrangement of the Pockels cell detector includes collimated laser light passing through a transparent birefringent crystal, located between crossed polarizers, and focused upon a photodiode. The birefringent crystal, CdZnTe in this case, is placed in a neutron beam emanating from a nuclear reactor beam port. After obtaining the voltage-dependent Pockels characteristic response curve with a photodiode, neutron measurements were conducted from reactor pulses with the Pockels cell set at the 1/4 and 3/4 wave bias voltages. The detector responses to nuclear reactor pulses were recorded in real-time using data logging electronics, each showing a sharp increase in photodiode current for the 1/4 wave bias, and a sharp decrease in photodiode current for the 3/4 wave bias. The polarizers were readjusted to equal angles in which the maximum light transmission occurred at 0 V bias, thereby, inverting the detector response to reactor pulses. A high sample rate oscilloscope was also used to more accurately measure the FWHM of the pulse from the electro-optic detector, 64 ms, and is compared to the experimentally obtained FWHM of 16.0 ms obtained with the B-lined counter. & 2012 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Nuclear Sources by UAV Teleoperation Using a Visuo-Haptic Augmented Reality Interface

A visuo-haptic augmented reality (VHAR) interface is presented enabling an operator to teleoperate an unmanned aerial vehicle (UAV) equipped with a custom CdZnTe-based spectroscopic gamma-ray detector in outdoor environments. The task is to localize nuclear radiation sources, whose location is unknown to the user, without the close exposure of the operator. The developed detector also enables i...

متن کامل

Progress in the Development of CdZnTe Unipolar Detectors for Different Anode Geometries and Data Corrections

CdZnTe detectors have been under development for the past two decades, providing good stopping power for gamma rays, lightweight camera heads and improved energy resolution. However, the performance of this type of detector is limited primarily by incomplete charge collection problems resulting from charge carriers trapping. This paper is a review of the progress in the development of CdZnTe un...

متن کامل

Infrared LED Enhanced Spectroscopic CdZnTe Detector Working under High Fluxes of X-rays

This paper describes an application of infrared light-induced de-polarization applied on a polarized CdZnTe detector working under high radiation fluxes. We newly demonstrate the influence of a high flux of X-rays and simultaneous 1200-nm LED illumination on the spectroscopic properties of a CdZnTe detector. CdZnTe detectors operating under high radiation fluxes usually suffer from the polariza...

متن کامل

Angular response of a W-collimated room-temperature-operated CdZnTe Frisch collar spectrometer

The spatial resolution of a collimated CdZnTe Frisch collar detector was experimentally investigated for two different tungsten collimator designs using a Au gamma-ray source at 412 keV. A two-dimensional model for the detector–collimator–source geometry was developed and applied with some simplifying assumptions. The CdZnTe detector was fabricated from a single crystal using a copper shim as t...

متن کامل

Spectrometric Performances of CdTe and CdZnTe Spectrometric Semiconductor Detector Arrays at High X-Ray Flux

The development of a novel energy resolved fast Xray imaging detector is reported. The device is based on pixellated cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) detectors coupled to a custom designed 16-channel fast spectroscopy front-end electronic circuit. For each channel, a fast Analog to Digital Converter (ADC) continuously digitizes the signal from the detector pixel. A F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012