Micro-Computed Tomography Provides Accurate Measurement for Cardiac Function in Infarcted Rat Heart

نویسندگان

  • Satoshi Matsushita
  • Mayuko Naito
  • Atsushi Amano
چکیده

Objective: High resolution image is required for accurate measurement of cardiac function for the analysis of detailed regional function especially in a small animal. Methods: Left ventricular function of rat hearts was measured using micro-computed tomography (micro-CT) with administration of contrast agent in a rat with normal heart as well as rats with mild and severe myocardial infarction (MI). Following the CT acquisition, the hearts were sectioned for pathological evaluation. Results: The volume plot per each disk of the normal heart revealed that contraction force peaked at the middle of the heart. In the heart with mild infarction, the volume plot curve clearly demonstrated that infarction was located only at the apex of the heart, whereas severe infarction was disturbed in larger area. The left ventricular ejection fraction of the normal, mild MI, and severe MI hearts were 68.6%, 40.0%, and 16.4%, respectively. In addition, volume analysis in severe MI demonstrated ventricular dilatation, although that in mild MI did not show any change in the ventricular volume. Histological results were consistent with the CT measurement. Conclusions: Micro-CT provided accurate measurement of cardiac function in rats, which is especially useful for the analysis of small animals with heterogeneous dysfunction of the heart.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid microcomputed tomography suggests cardiac enlargement occurs during conductance catheter measurements in mice.

Conductance catheters (CC) represent an established method of determining cardiac function in mice; however, the potentially detrimental effects a catheter may have on the mouse heart have never been evaluated. The present study takes advantage of rapid three-dimensional (3D) microcomputed tomography (CT) to compare simultaneously acquired micro-CT and CC measurements of left ventricular (LV) v...

متن کامل

Siemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

متن کامل

Human iPS cell-engineered cardiac tissue sheets with cardiomyocytes and vascular cells for cardiac regeneration

To realize cardiac regeneration using human induced pluripotent stem cells (hiPSCs), strategies for cell preparation, tissue engineering and transplantation must be explored. Here we report a new protocol for the simultaneous induction of cardiomyocytes (CMs) and vascular cells [endothelial cells (ECs)/vascular mural cells (MCs)], and generate entirely hiPSC-engineered cardiovascular cell sheet...

متن کامل

Feasibility of using Medical Imaging Interaction Toolkit in volumetric studies to accurate diagnosing of vascular emboli by Extended NURBS-based Cardiac-Torso phantom

Introduction: Important complications of venous thromboembolism (VTE) are a longer hospital stay, readmission, recurrence of the emboli, complications of anticoagulant therapy and death in a sever condition. In present study, the volume measurement accuracy of the medical imaging interaction toolkit (MITK) software on determining VTE in computed tomography images was evaluated....

متن کامل

Catheter-Based Intramyocardial Delivery (NavX) of Adenovirus Achieves Safe and Accurate Gene Transfer in Pigs

BACKGROUND Hepatocyte growth factor (HGF) is one of the major angiogenic factors being studied for the treatment of ischemic heart diseases. Our previous study demonstrated adenovirus-HGF was effective in myocardial ischemia models. The first clinical safety study showed a positive effect in patients with severe and diffused triple coronary disease. METHODS 12 Pigs were randomized (1:1) to re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014