Super-Positioning of Voltage Sources for Fast Assessment of Wide-Area Thévenin Equivalents
نویسندگان
چکیده
A method for superimposing voltage sources is sought optimized by using a sparse triangular solver and multiprocessing. A revision to the method is suggested which exploits Schur’s complement of the network admittance matrix and optimal re-use of computations. The algorithm is implemented and parallelized for shared memory multiprocessing. The proposed algorithm is tested on a collection of large test systems and performance is found to be significantly better than the reference method. The algorithm will thereby facilitate a speed-up of methods relying on Thévenin Equivalent representation such as the Thévenin equivalent method for contingency assessment.
منابع مشابه
A Fast Voltage Collapse Detection and Prevention Based on Wide Area Monitoring and Control
Voltage stability is one of the most important factors in maintaining reliable operation of power systems. When a disturbance occurs in the power system, it usually causes instabilities and sometimes leads to voltage collapse (VC). To avoid such problems, a novel approach called Vector Analysis (VA) is proposed that exploits a new instability detection index to provide wide area voltage stabili...
متن کاملNeuro-Fuzzy Based Algorithm for Online Dynamic Voltage Stability Status Prediction Using Wide-Area Phasor Measurements
In this paper, a novel neuro-fuzzy based method combined with a feature selection technique is proposed for online dynamic voltage stability status prediction of power system. This technique uses synchronized phasors measured by phasor measurement units (PMUs) in a wide-area measurement system. In order to minimize the number of neuro-fuzzy inputs, training time and complication of neuro-fuzzy ...
متن کاملOnline Inertia Constant and Thévenin Equivalent Estimation Using PMU Data
In this paper a new algorithm based on phasor measurements for estimating the Thévenin Equivalent (TE) and system inertia constant is proposed. The method estimates the network TE seen from a generator terminal and equivalent system inertia constant by means of phasor data that is available at Phasor Data Concentrator (PDC) center. It is shown that the parameters of the TE could be estimated at...
متن کاملParallel Computation of Large Power System Network Solutions Using the Multi-Area Thevenin Equivalents (MATE) Algorithm
An implementation of the Multi-Area Thévenin Equivalents (MATE) partitioning framework for the parallel solution of large power system matrices is described in this paper. The solution of the Western Electricity Coordinating Council system (∼15,000 buses) obtained using both traditional sparsity techniques and MATE were compared. The MATE algorithm achieved speedups of up to 7 times with respec...
متن کاملModified Impedance-Based OOS Protection Based on On-Line Thévenin Equivalent Estimation
In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- IEEE Trans. Smart Grid
دوره 8 شماره
صفحات -
تاریخ انتشار 2017