Experiences of the first 16 hospitals using copper-silver ionization for Legionella control: implications for the evaluation of other disinfection modalities.

نویسندگان

  • Janet E Stout
  • Victor L Yu
چکیده

BACKGROUND AND OBJECTIVES Hospital-acquired legionnaires' disease can be prevented by disinfection of hospital water systems. This study assessed the long-term efficacy of copper-silver ionization as a disinfection method in controlling Legionella in hospital water systems and reducing the incidence of hospital-acquired legionnaires' disease. A standardized, evidence-based approach to assist hospitals with decision making concerning the possible purchase of a disinfection system is presented. DESIGN The first 16 hospitals to install copper-silver ionization systems for Legionella disinfection were surveyed. Surveys conducted in 1995 and 2000 documented the experiences of the hospitals with maintenance of the system, contamination of water with Legionella, and occurrence of hospital-acquired legionnaires' disease. All were acute care hospitals with a mean of 435 beds. RESULTS All 16 hospitals reported cases of hospital-acquired legionnaires' disease prior to installing the copper-silver ionization system. Seventy-five percent had previously attempted other disinfection methods including superheat and flush, ultraviolet light, and hyperchlorination. By 2000, the ionization systems had been operational from 5 to 11 years. Prior to installation, 47% of the hospitals reported that more than 30% of distal water sites yielded Legionella. In 1995, after installation, 50% of the hospitals reported 0% positivity, and 43% still reported 0% in 2000. Moreover, no cases of hospital-acquired legionnaires' disease have occurred in any hospital since 1995. CONCLUSIONS This study represents the final step in a proposed 4-step evaluation process of disinfection systems that includes (1) demonstrated efficacy of Legionella eradication in vitro using laboratory assays, (2) anecdotal experiences in preventing legionnaires' disease in individual hospitals, (3) controlled studies in individual hospitals, and (4) validation in confirmatory reports from multiple hospitals during a prolonged time (5 to 11 years in this study). Copper-silver ionization is now the only disinfection modality to have fulfilled all four evaluation criteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of copper and silver ionization on fungal colonization of the water supply in health care centers: implications for immunocompromised patients.

Copper and silver ionization is a well-recognized disinfection method to control Legionella species in water distribution systems in hospitals. These systems may also serve as a potential indoor reservoir for fungi. The prevalence of fungi was significantly lower in ionized than in nonionized water samples from health care facilities. The clinical consequences of this finding require further in...

متن کامل

Intermittent use of copper-silver ionization for Legionella control in water distribution systems: a potential option in buildings housing individuals at low risk of infection.

One copper-silver ionization system was sequentially installed onto the hot-water recirculation lines of two hospital buildings colonized with Legionella pneumophila, serogroup 1. A third building with the same water supply and also colonized with Legionella served as a control. Four weeks after activation of the system, distal site positivity for Legionella in the first test building dropped t...

متن کامل

Controlling Legionella in hospital drinking water: an evidence-based review of disinfection methods.

Hospital-acquired Legionnaires' disease is directly linked to the presence of Legionella in hospital drinking water. Disinfecting the drinking water system is an effective preventive measure. The efficacy of any disinfection measures should be validated in a stepwise fashion from laboratory assessment to a controlled multiple-hospital evaluation over a prolonged period of time. In this review, ...

متن کامل

Hospital-acquired legionnaires disease in a university hospital: impact of the copper-silver ionization system.

We evaluated the impact of the copper-silver ionization system in a hospital where hyperendemic nosocomial legionellosis and was present and all previous disinfection measures had failed. After implementation of the copper-silver ionization system, environmental colonization with Legionella species decreased significantly, and the incidence of nosocomial legionellosis decreased dramatically, fr...

متن کامل

Legionella control by chlorine dioxide in hospital water systems

egionnaires’ disease is caused by Legionella bacteria, which colonize 12–70% of hospital water systems (Lin et al, 1998b). Of the Legionnaires’ disease cases reported to the Centers for Disease Control and Prevention (CDC), 25–45% were hospital-acquired (Benin et al, 2002). Legionella and other opportunistic pathogens colonize water systems; cause pneumonia, wound, and bloodstream infections in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Infection control and hospital epidemiology

دوره 24 8  شماره 

صفحات  -

تاریخ انتشار 2003