In vitro corrosion behaviour of titanium alloys without vanadium

نویسندگان

  • M. F. López
  • A. Gutiérrez
چکیده

The corrosion behaviour of three new non-toxic titanium alloys for use as biomaterials has been investigated. The corrosion current densities of these Ti alloys have low values, indicating a passive state that is stable with time. These values were calculated by using both direct and alternate current methods. The comparison with Ti–6Al–4V, widely used as biomaterial, shows slightly lower corrosion rates for the non V-containing alloys. To determine the pitting corrosion resistance, anodic polarisation curves were performed. Those alloys containing Zr, with very low passivation current densities, show the best behaviour. This indicates a low susceptibility to localised corrosion in these alloys. The chemical surface analysis performed on the samples suggests an influence of the passive layer composition on the passivation current density. © 2002 Elsevier Science Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corrosion behaviour of polished and sandblasted titanium alloys in PBS solution.

In this work, we performed comparative studies of the effect of surface preparation of Ti6Al4V and Ti6Al7Nb biomedical alloys and the influence of endothelial cells on their corrosion behaviour in PBS (Phosphate Buffered Saline). Two different methods of surface modification were applied - polishing and sandblasting. The polished Ti6Al7Nb alloy was found to have the best resistance against gene...

متن کامل

Evaluation of Biocompatibility for Titanium-Nickel Shape Memory Alloy in Vivo and in Vitro Environments

This study was conducted to evaluate the biocompatibility of titanium-nickel shape memory alloy used as a medical implant material. The authors carried out the following electrochemical corrosion test and in vivo and in vitro biological tests for the alloy and some metal and alloys clinically used previously to compare the intensities concerned with the biological reactions, that is, (1) anodic...

متن کامل

Allergic reaction to vanadium causes a diffuse eczematous eruption and titanium alloy orthopedic implant failure.

Allergy as a cause of adverse outcomes in patients with implanted orthopedic hardware is controversial. Allergy to titanium-based implants has not been well researched, as titanium is traditionally thought to be inert. We highlight the case of a patient who developed systemic dermatitis and implant failure after surgical placement of a titanium alloy (Ti6Al4V) plate in the left foot. The hardwa...

متن کامل

Evaluation of Plasma Nitriding Efficiency of Titanium Alloys for Medical Applications

Wide use of titanium alloys results from their unique physical and chemical properties 1 . Combination of low density and improved corrosion resistance with good plasticity and mechanical properties determines application of titanium alloys in such industries as aviation, automotive, power and shipbuilding industries or architecture as well as medicine and sports equipment. Despite numerous adv...

متن کامل

In vitro biocompatibility evaluation of surface-modified titanium alloys.

The present work is aimed to evaluate the effects of a surface modification process on the biocompatibility of three vanadium-free titanium alloys with biomedical applications interest. Chemical composition of alloys investigated, in weight %, were Ti-7Nb-6Al, Ti-13Nb-13Zr, and Ti-15Zr-4Nb. An easy and economic method intended to improve the biocompatibiblity of these materials consists in a si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002