Discussing the influence of electrode location in the result of esophageal prolonged pH monitoring

نویسندگان

  • Valter Nilton Felix
  • Ioshiaki Yogi
  • Daniel Senday
  • Fernando Tadeu Vannucci Coimbra
  • David Pares
  • Vinicius Garcia
  • Carlos Eduardo Garcia
چکیده

BACKGROUND There is a large consensus to preserve the distance of 5 cm above the proximal border of the lower esophageal sphincter (PBLES) as appropriate to the location of the electrode of the pH-metry. The main objective of this study is to determine whether placement of the electrode below the recommended location achieves a significant difference in the calculation of the DeMeester score. METHODS The study was made up of 60 GERD patients and 20 control subjects. They were submitted to esophageal manometry and to pH-metric examination with two pH-metric catheters contained antimony electrodes - the distal was positioned 3 cm above the PBLES, leaving the other 5 cm away from it. RESULTS LES pressure (LESP) in the GERD group was significantly lower than in the control group (P = 0.005). Normal mean DeMeester score was observed simultaneously in the control group, by both the electrodes, but abnormal DeMeester score was much more expressive when observed by the distal electrode in the GERD group. There were significant differences as for DeMeester score, of patients with GERD from that of the control group and of distal from the proximal electrode in the GERD group. CONCLUSIONS Acid reflux is directly related to lower levels of LESP. Lower location of the catheter may strongly affect the results of prolonged esophageal pH monitoring in GERD patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct DNA Immobilization onto a Carbon Nanotube Modified Electrode: Study on the Influence of pH and Ionic Strength

Over the past years, DNA biosensors have been developed to analyze DNA interaction and damage that have important applications in biotechnological researches. The immobilization of DNA onto a substrate is one key step for construction of DNA electrochemical biosensors. In this report, a direct approach has been described for immobilization of single strand DNA onto carboxylic acid-functionalize...

متن کامل

Indoor air quality monitoring in urban areas using Smart Sensing Technology

Recently, indoor air quality has attracted the attention of policymakers and researchers as a critical issue like that of external air pollution. Indoor air quality is more important as people spend time longer indoors than outdoors. Indoor environments are closed compared to external environments providing less opportunity for the pollutants to dilute. The emissions contain many substances tha...

متن کامل

EFFICIENCY EVALUATION OF PROPOSED OBJECTIVE FUNCTIONS IN STRUCTURAL DAMAGE DETECTION BASED ON MODAL STRAIN ENERGY AND FLEXIBILITY APPROACHES

Civil infrastructures such as bridges and buildings are prone to damage as a result of natural disasters. To understand damages induced by these events, the structure needs to be monitored. The field of engineering focusing on the process of evaluating the location and the intensity of the damage to the structure is called Structural Health Monitoring (SHM). Early damage prognosis in structures...

متن کامل

Study on Electrochemical Oxidation of m-Nitrophenol on Various Electrodes Using Cyclic Voltammetry

The electrochemical oxidation behavior of m-nitrophenol (m-NP) was studied comparatively on glassy carbon electrode, Pt electrode, PbO2 electrode, SnO2 electrode, and graphite electrode using cyclic voltammetry. The cyclic voltammetry measurements were performed in acidic (1 M H2SO4, pH 0.4), neutral (1 M Na2SO4, pH 6.8), and...

متن کامل

Congenital Esophageal Stenosis Associated with Esophageal Atresia and Gasless Abdomen

SUMMARY A radiologically gasless abdomen in a neonate with EA is usually regarded as being pathognomonic of an absence of distal T.E.F. It has been estimated that up to 1.5% of patient with a distal fistula may have a radiologically gasless abdomens as a manifestation of a very small fistula plugged with mucus. In this case a contrast study via the gastrostomy demonstrated a fistula between th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014