Pressure-derived measurement of coronary flow reserve.

نویسندگان

  • Philip MacCarthy
  • Alexandre Berger
  • Ganesh Manoharan
  • Jozef Bartunek
  • Emanuele Barbato
  • William Wijns
  • Guy R Heyndrickx
  • Nico H J Pijls
  • Bernard De Bruyne
چکیده

OBJECTIVES We aimed to validate the technique of measuring the coronary flow reserve (CFR) with coronary pressure measurements against an established thermodilution technique. BACKGROUND The CFR has traditionally required measurement of coronary blood flow velocity with the Doppler wire and, more recently, using a thermodilution technique with the coronary pressure wire. However, recent work has suggested that the CFR may be derived from pressure measurements alone (the ratio of the square root of the pressure drop across an epicardial stenosis during hyperemia to that value at rest). This depends on the assumption that friction losses across a coronary stenosis are negligible. METHODS We compared pressure-derived CFR values with those obtained by the thermodilution technique using the intracoronary pressure wire in 38 stenoses in 34 patients with significant coronary stenoses undergoing percutaneous intervention. We also compared these two techniques of measuring CFR in 25 stenoses (6 vessels) artificially created by inflating small balloons within a stented coronary artery after percutaneous intervention. RESULTS There is a close linear relationship between pressure-derived and thermodilution CFR in native (r(2) = 0.52; p < 0.001) and artificial stenoses (r(2) = 0.54; p < 0.05), although the pressure-derived technique appears to systematically underestimate CFR values in both situations. This applies to native and artificial stenoses. CONCLUSIONS Coronary flow reserve cannot be measured merely with pressure alone, and it cannot be safely assumed that friction losses are negligible across a native coronary stenosis. These data suggest that friction loss is an important determinant of the pressure gradient along an atherosclerotic coronary artery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary pressure measurement and fractional flow reserve.

The shortcomings of coronary arteriography to assess the physiological significance of coronary stenoses have been recognised for decades ; therefore, the importance of additional physiological techniques is beyond doubt. One of the currently available physiological techniques is coronary pressure measurement, which has emerged over the past few years as a major step forward in the invasive ass...

متن کامل

Fundamentals in clinical coronary physiology: why coronary flow is more important than coronary pressure.

Wide attention for the appropriateness of coronary stenting in stable ischaemic heart disease (IHD) has increased interest in coronary physiology to guide decision making. For many, coronary physiology equals the measurement of coronary pressure to calculate the fractional flow reserve (FFR). While accumulating evidence supports the contention that FFR-guided revascularization is superior to re...

متن کامل

Utilization of translesional hemodynamics: comparison of pressure and flow methods in stenosis assessment in patients with coronary artery disease.

Aim of this study is the assessment of feasibility and clinical usefulness of a new index of stenosis severity, the slope of the instantaneous transstenotic pressure gradient/velocity relationship. Twenty-one patients scheduled for percutaneous revascularization procedures were studied with simultaneous measurement of poststenotic coronary pressure and flow velocity, in basal condition and duri...

متن کامل

Coronary physiology revisited : practical insights from the cardiac catheterization laboratory.

Various coronary physiological measurements can be made in the cardiac catheterization laboratory using sensor-tipped guidewires; they include the measurement of poststenotic absolute coronary flow reserve, the relative coronary flow reserve, and the pressure-derived fractional flow reserve of the myocardium. Ambiguity regarding abnormal microcirculation has been reduced or eliminated with meas...

متن کامل

Validation of collateral fractional flow reserve by myocardial perfusion imaging.

BACKGROUND Collateral fractional flow reserve (FFR(coll)) is an index to quantify collateral blood flow, derived from coronary pressure measurements. Although well defined theoretically, its direct validation by myocardial perfusion imaging has not been established so far. Validating this index by myocardial perfusion imaging is the main aim of this study. METHODS AND RESULTS Twenty-four cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 45 2  شماره 

صفحات  -

تاریخ انتشار 2005